Commit 2760b7a
powerpc/tau: Use appropriate temperature sample interval
[ Upstream commit 6694300 ]
According to the MPC750 Users Manual, the SITV value in Thermal
Management Register 3 is 13 bits long. The present code calculates the
SITV value as 60 * 500 cycles. This would overflow to give 10 us on
a 500 MHz CPU rather than the intended 60 us. (But according to the
Microprocessor Datasheet, there is also a factor of 266 that has to be
applied to this value on certain parts i.e. speed sort above 266 MHz.)
Always use the maximum cycle count, as recommended by the Datasheet.
Fixes: 1da177e ("Linux-2.6.12-rc2")
Signed-off-by: Finn Thain <fthain@telegraphics.com.au>
Tested-by: Stan Johnson <userm57@yahoo.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Link: https://lore.kernel.org/r/896f542e5f0f1d6cf8218524c2b67d79f3d69b3c.1599260540.git.fthain@telegraphics.com.au
Signed-off-by: Sasha Levin <sashal@kernel.org>1 parent c38ae2b commit 2760b7a
2 files changed
+5
-9
lines changed| Original file line number | Diff line number | Diff line change | |
|---|---|---|---|
| |||
817 | 817 | | |
818 | 818 | | |
819 | 819 | | |
820 | | - | |
| 820 | + | |
821 | 821 | | |
822 | 822 | | |
823 | 823 | | |
| |||
| Original file line number | Diff line number | Diff line change | |
|---|---|---|---|
| |||
178 | 178 | | |
179 | 179 | | |
180 | 180 | | |
181 | | - | |
182 | | - | |
183 | | - | |
184 | | - | |
185 | | - | |
186 | | - | |
187 | | - | |
| 181 | + | |
| 182 | + | |
| 183 | + | |
188 | 184 | | |
189 | | - | |
| 185 | + | |
190 | 186 | | |
191 | 187 | | |
192 | 188 | | |
| |||
0 commit comments