Purpose: confirm that the extraordinarily large effect sizes reported in PHASE5_PART2_COMPARE.md (|d| up to 649) are a correct consequence of this benchmark's controlled-environment minimal variance, not a formula or unit bug in src/harness/stats.js.

Method

Re-compute Cohen's d by hand from the raw jankRate values in the committed JSONL files:

  • docs/PHASE5_PART1_RESULTS.jsonl (120 runs)
  • docs/PHASE5_PART2_RESULTS.jsonl (88 runs)

Formula (Cohen 1988, standard pooled-SD form):

pooled_sd = sqrt(((n_A - 1) * var_A + (n_B - 1) * var_B) / (n_A + n_B - 2))
d         = (mean_A - mean_B) / pooled_sd

where var_* is the sample variance (denominator n - 1). Implementation in src/harness/stats.js::cohensD uses this exact form.

Raw computations

All three pre-registered comparison tables. Cell key: A vs B.

Table (a) — Scratch (Part 1) vs Pretrained + Online (Part 2)

Workload n_A mean_A sd_A n_B mean_B sd_B pooled_sd d_manual d_analyze match
sawtooth 10 6.623 % 0.2786 pp 10 4.593 % 0.1229 pp 0.2153 pp +9.4281 +9.4281
burst 10 5.455 % 0.0213 pp 10 5.515 % 0.0487 pp 0.0376 pp −1.6064 −1.6064
scroll 10 7.076 % 0.1860 pp 10 6.784 % 0.2919 pp 0.2447 pp +1.1943 +1.1943

Table (b) — Pretrained + Online vs Pretrained + Frozen

Workload n_A mean_A sd_A n_B mean_B sd_B pooled_sd d_manual d_analyze match
sawtooth 10 4.593 % 0.1229 pp 10 11.679 % 0.0224 pp 0.0883 pp −80.2267 −80.2267
burst 10 5.515 % 0.0487 pp 10 5.523 % 0.0388 pp 0.0440 pp −0.1724 −0.1724
scroll 10 6.784 % 0.2919 pp 10 14.606 % 0.1431 pp 0.2299 pp −34.0306 −34.0306

Table (c) — B1 vs Pretrained + Frozen (blog headline)

Workload n_A mean_A sd_A n_B mean_B sd_B pooled_sd d_manual d_analyze match
sawtooth 12 1.664 % 0.0048 pp 10 11.679 % 0.0224 pp 0.0154 pp −649.3136 −649.3136
burst 12 5.559 % 0.0009 pp 10 5.523 % 0.0388 pp 0.0260 pp +1.4149 +1.4149
scroll 12 3.383 % 0.0277 pp 10 14.606 % 0.1431 pp 0.0981 pp −114.3681 −114.3681

Verdict

Scenario (a) — computation is correct; standard deviations are legitimately tiny.

Every manual value matches the corresponding analyze.js output bit-for- bit. The extraordinary effect sizes follow directly from standard deviations that are orders of magnitude smaller than what Cohen's "small / medium / large" conventions (d = 0.2 / 0.5 / 0.8) were calibrated against. That calibration came from naturally-noisy human-subjects research; this benchmark is a controlled synthetic environment.

Why variance is minimal:

  1. B1 is fully deterministic. Seed = 42 + identical dt sequences through an EMA threshold produces byte-identical decisions every run. Its residual SD (~0.005 pp) is pure Float32 quantization of the summary metrics — no real variance.
  2. Pretrained + Frozen is also fully deterministic. No weight updates during measurement, so the Predictor is a pure function of its (frozen) 353 parameters and the feature stream. Same seed → same decisions → same metrics modulo float noise.
  3. Headless no-vsync regime. scripts/benchmark.js runs with --disable-background-timer-throttling and --disable-backgrounding-occluded-windows; the rAF loop is dispatched by CPU work completion, not by a 60 Hz refresh signal. This removes wall-clock jitter that would otherwise show up as variance.

When both cells in a comparison are deterministic (as in table (c)'s sawtooth cell — B1 and Pretrained+Frozen), pooled SD collapses to order 1e-4, and any real mean shift produces a d of comparable magnitude. d = −649 on sawtooth's (c) cell decomposes to |Δμ| = 10.01 pp ÷ pooled_sd = 0.015 pp — both numerators and denominators are correct.

Practical interpretation

Under these measurement conditions, Cohen's d primarily encodes "this mean shift exceeds the measurement noise floor." At a 0.015 pp noise floor, that is a very weak statement. The blog post and RESULTS.md should read effect direction + absolute percentage-point shift as the practical magnitude, and treat d only as a "not-noise" qualifier.

Accordingly, RESULTS.md's Part 2 section now reports |Δ| in pp alongside every d. The existing d values stay — they are correct — but the accompanying prose directs readers to the pp figure for practical interpretation, with a one-paragraph note explaining why d inflates in controlled measurement regimes.

Action

No code change required. This document is the record that the d values were validated and the inflated magnitudes are a property of the measurement environment, not a bug.