What happened?
The remote does not seem to support battery readout. It's always null and I get the following when configuring:
z2m: Failed to configure '0xXXXXXXXXXXXXXXXX', attempt 1 (Error: ZCL command 0x0xXXXXXXXXXXXXXXXX/1 genPowerCfg.configReport([{"minimumReportInterval":3600,"maximumReportInterval":65000,"reportableChange":10,"attribute":"batteryPercentageRemaining"}], {"timeout":10000,"disableResponse":false,"disableRecovery":false,"disableDefaultResponse":true,"direction":0,"reservedBits":0,"writeUndiv":false}) failed (Status 'UNSUP_GENERAL_COMMAND') at Endpoint.checkStatus (/app/node_modules/.pnpm/zigbee-herdsman@10.4.0/node_modules/zigbee-herdsman/src/controller/model/endpoint.ts:458:28) at Endpoint.zclCommand (/app/node_modules/.pnpm/zigbee-herdsman@10.4.0/node_modules/zigbee-herdsman/src/controller/model/endpoint.ts:1179:26) at Endpoint.configureReporting (/app/node_modules/.pnpm/zigbee-herdsman@10.4.0/node_modules/zigbee-herdsman/src/controller/model/endpoint.ts:868:9) at setupAttributes (/app/node_modules/.pnpm/zigbee-herdsman-converters@26.63.0/node_modules/zigbee-herdsman-converters/src/lib/modernExtend.ts:173:17) at configure (/app/node_modules/.pnpm/zigbee-herdsman-converters@26.63.0/node_modules/zigbee-herdsman-converters/src/lib/modernExtend.ts:235:17) at Object.configure (/app/node_modules/.pnpm/zigbee-herdsman-converters@26.63.0/node_modules/zigbee-herdsman-converters/src/index.ts:363:21) at Configure.configure (/app/lib/extension/configure.ts:135:13) at EventEmitter.wrappedCallback (/app/lib/eventBus.ts:252:17))
As far as I can tell it's always null in #28547 as well. I could be wrong of course, curious on other people's feedback. CC: @tonyschuite @doogstar @hlathome
What did you expect to happen?
See the battery %, pair/configure without errors.
How to reproduce it (minimal and precise)
Try to pair/configure, or refresh battery level.
Zigbee2MQTT version
2.12.0
Adapter firmware version
Revision: 8.0.2 [GA]
Adapter
Sonoff mg24, using ember
Setup
Docker
Device database.db entry
No response
Debug log
No response
Notes
No response
What happened?
The remote does not seem to support battery readout. It's always null and I get the following when configuring:
As far as I can tell it's always null in #28547 as well. I could be wrong of course, curious on other people's feedback. CC: @tonyschuite @doogstar @hlathome
What did you expect to happen?
See the battery %, pair/configure without errors.
How to reproduce it (minimal and precise)
Try to pair/configure, or refresh battery level.
Zigbee2MQTT version
2.12.0
Adapter firmware version
Revision: 8.0.2 [GA]
Adapter
Sonoff mg24, using ember
Setup
Docker
Device
database.dbentryNo response
Debug log
No response
Notes
No response