<pstyle=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;"><spanstyle=" font-size:14pt;">This is a 3d representation of probe starting and finishing points of inside probing.</span></p>
9
9
<pstyle=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;"><spanstyle=" font-size:14pt;">The probe starting placement is approximately on the intersection of edges.</span></p>
10
-
<pstyle=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;"><spanstyle=" font-size:14pt;">the green cross-hair is the finishing position after probing.</span></p></body></html>
10
+
<pstyle=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;"><spanstyle=" font-size:14pt;">The green cross-hair is the finishing position after probing.</span></p></body></html>
<pstyle=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;"><spanstyle=" font-size:14pt;">Demo of inside corner probing using the top right button in Basic Probe (</span><spanstyle=" font-size:14pt; font-weight:600;">back_right_inside</span><spanstyle=" font-size:14pt;">).</span></p>
10
10
<pstyle=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;"><spanstyle=" font-size:14pt;">While all probe entries must be correct, the most important settings to change for each probe sequence:</span></p>
@@ -15,13 +15,13 @@
15
15
<pstyle=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;"><spanstyle=" font-size:14pt;">* </span><spanstyle=" font-size:14pt; font-weight:600;">EDGE WIDTH</span><spanstyle=" font-size:14pt;"> -distance along edge wall (away from corner) to start probing.</span></p>
<pstyle=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;"><spanstyle=" font-size:14pt;">These distance are always to be set in 'machine units' (mm for metric machine, inch for imprial machine)</span></p>
18
+
<pstyle=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;"><spanstyle=" font-size:14pt;">These distances are always to be set in 'machine units' (mm for metric machine, inch for imperial machine)</span></p>
<ulstyle="margin-top: 0px; margin-bottom: 0px; margin-left: 0px; margin-right: 0px; -qt-list-indent: 1;"><listyle=" font-size:14pt;" style=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">manual set probe at the intersection of the edges (ie corner) of material as described by the green bullseye on the button. Set it Z CLEARANCE above the top of material. These can be done by eye.</li></ul>
<ulstyle="margin-top: 0px; margin-bottom: 0px; margin-left: 0px; margin-right: 0px; -qt-list-indent: 1;"><listyle=" font-size:14pt;" style=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">set EXTRA CLEARANCE to a value that you want the probe to go below the _top_ of material.(So the probe will move from it's start position down Z Clearance + Extra Clearance distance)</li></ul>
24
+
<ulstyle="margin-top: 0px; margin-bottom: 0px; margin-left: 0px; margin-right: 0px; -qt-list-indent: 1;"><listyle=" font-size:14pt;" style=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">set EXTRA DEPTH to a value that you want the probe to go below the _top_ of material.(So the probe will move from its start position down Z Clearance + Extra Depth distance)</li></ul>
<ulstyle="margin-top: 0px; margin-bottom: 0px; margin-left: 0px; margin-right: 0px; -qt-list-indent: 1;"><listyle=" font-size:14pt;" style=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;"> set XY CLEARANCE to a value that definitely gives clearance from the wall so when the probe goes down it doesn't hit anything.</li>
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">The maximum distance that the probe will travel during the initial search. If the search distance is too short, you will receive a message like "G38 finished without making contact". For safety reasons, it is recommended to set this parameter to 3-4 mm more than probe stylus diameter. Z travel used for straight down probing.</p>
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">The distance the probe is retracted after making initial contact with the workpiece. This should be a short distance because the second approach will be at a slow speed, but large enough for the probe to break contact and bring it to the search ready state. If the Latch Rtn distance too large, you will end up spending a lot of time waiting for the search to complete. Recommendation: 1-2 mm </p>
11
+
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">The distance the probe is retracted after making initial contact with the workpiece. This should be a short distance because the second approach will be at a slow speed, but large enough for the probe to break contact and bring it to the search ready state. If the Latch Rtn distance is too large, you will end up spending a lot of time waiting for the search to complete. Recommendation: 1-2 mm </p>
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">The height of the tool sensor from the machine table surface. This value is used to calculate the Z zero height for the current work coordinate system when using the probe with a tool setter sensor. </p>
<palign="center" style=" margin-top:0px; margin-bottom:0px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">Sequence of movements for Outside Corner </p>
9
9
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">Manually jog the probe tip to about 2-10 mm above the workpiece surface.</p>
10
10
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">Manually jog the XY position to about the position indicated by the colored dot on the appropriate button of the Probe Screen.</p>
11
11
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">Set the (edge)<spanstyle=" font-weight:600;"> length </span>to have the probe move along the edge (away from the corner) the desired distance.</p>
12
-
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">Set the (edge)<spanstyle=" font-weight:600;"> XY (clearence) </span>to have the probe move away from the edge for probe clearence when lowring the probe in Z .If the <spanstyle=" font-weight:600;">XY (clearence) </span>moves the probe farther away then the probe maximum<spanstyle=" font-weight:600;"> Z travel </span>distance, the probing will fail.</p>
13
-
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">Set the (edge)<spanstyle=" font-weight:600;"> Z (clearence) </span>to have the probe move down the desired distance for clean material probing.</p></body></html>
12
+
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">Set the (edge)<spanstyle=" font-weight:600;"> XY (clearance) </span>to have the probe move away from the edge for probe clearance when lowering the probe in Z. If the <spanstyle=" font-weight:600;">XY (clearance) </span>moves the probe farther away than the probe maximum<spanstyle=" font-weight:600;"> Z travel </span>distance, the probing will fail.</p>
13
+
<pstyle=" margin-top:12px; margin-bottom:12px; margin-left:0px; margin-right:0px; -qt-block-indent:0; text-indent:0px;">Set the (edge)<spanstyle=" font-weight:600;"> Z (clearance) </span>to have the probe move down the desired distance for clean material probing.</p></body></html>
0 commit comments