Notifications
You must be signed in to change notification settings - Fork 1.1k
Expand file tree
/
Copy pathPumpNodeManager.Configure.cs
More file actions
340 lines (303 loc) · 14.6 KB
/
Copy pathPumpNodeManager.Configure.cs
File metadata and controls
340 lines (303 loc) · 14.6 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
/* ========================================================================
* Copyright (c) 2005-2025 The OPC Foundation, Inc. All rights reserved.
*
* OPC Foundation MIT License 1.00
*
* Permission is hereby granted, free of charge, to any person
* obtaining a copy of this software and associated documentation
* files (the "Software"), to deal in the Software without
* restriction, including without limitation the rights to use,
* copy, modify, merge, publish, distribute, sublicense, and/or sell
* copies of the Software, and to permit persons to whom the
* Software is furnished to do so, subject to the following
* conditions:
*
* The above copyright notice and this permission notice shall be
* included in all copies or substantial portions of the Software.
* THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
* EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES
* OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
* NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT
* HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY,
* WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING
* FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR
* OTHER DEALINGS IN THE SOFTWARE.
*
* The complete license agreement can be found here:
* http://opcfoundation.org/License/MIT/1.00/
* ======================================================================*/
using System;
using System.Threading;
using Microsoft.Extensions.Logging;
using Opc.Ua;
using Opc.Ua.Pumps;
using Opc.Ua.Server.Fluent;
namespace Pumps
{
/// <summary>
/// Sibling partial that wires per-node callbacks for the
/// <see cref="PumpNodeManager"/> using the fluent builder.
/// Demonstrates the OPC 40223 Pumps companion specification
/// with a full simulation loop.
/// </summary>
/// <remarks>
/// The node manager is hand-written and uses the fluent
/// <see cref="INodeManagerBuilder"/> API to wire per-node
/// callbacks. See <see cref="Configure"/> for the entry point.
/// </remarks>
public partial class PumpNodeManager
{
/// <summary>
/// ── Simulation state ────────────────────────────────────────
/// </summary>
private long m_simulationTicks;
private long m_numberOfStarts;
/// <summary>
/// Reference to the hand-rolled Pump #1 instance so the
/// simulation tick can mutate its DI properties in response to
/// supervision flags. Set by CreatePumpInstanceAsync.
/// </summary>
private PumpState? m_pump1;
/// <summary>
/// Optional DI DeviceHealth variable supplied by a declarative
/// DeviceState device (e.g. Pump #2). Set via
/// RegisterSupervisedDeviceHealth and toggled by AdvanceSimulation
/// to reflect cavitation / motor-overheat states using the NAMUR
/// NE 107 enumeration.
/// </summary>
private BaseDataVariableState<Opc.Ua.Di.DeviceHealthEnumeration>?
m_supervisedDeviceHealth;
/// <summary>
/// ── Latest simulated values, updated by the simulation tick. ──
/// </summary>
private double m_currentPressure;
private double m_currentTemperature = 313.15;
private double m_currentBearingTemp = 333.15;
private double m_currentPower;
private double m_currentFlow;
private double m_currentEfficiency = 75.0;
private double m_currentLevel = 2.5;
private bool m_cavitation;
private bool m_motorOverheat;
partial void Configure(INodeManagerBuilder builder)
{
Server.Telemetry.CreateLogger<PumpNodeManager>()
.LogInformation("Configuring PumpNodeManager fluent wiring...");
WithIdentification(builder);
WithMeasurements(builder);
WithSupervision(builder);
// Single manager-owned simulation tick advances all live
// measurements at 250 ms intervals; lets time-based fault
// injection work cleanly.
builder.Simulation(TimeSpan.FromMilliseconds(250))
.OnTick((ctx, elapsed) => AdvanceSimulation());
}
/// <summary>
/// ── Identification properties via WithProperty ──────────────
/// PumpType.Identification is a mandatory child of PumpType so
/// it is materialised by the source-generated factory used in
/// CreatePumpInstanceAsync. BrowsePathResolver's cross-namespace
/// name-only fallback (FB-3 phase 1) resolves the unqualified
/// 'Identification' segment to the DI-namespace child without
/// requiring an explicit ns= prefix in the path.
/// </summary>
/// <param name="builder"></param>
private void WithIdentification(INodeManagerBuilder builder)
{
builder.Node("Pump #1/Identification")
.WithProperty("Manufacturer", "SimPump Corp")
.WithProperty("SerialNumber", "SN-001")
.WithProperty("ProductInstanceUri",
"urn:simdevice:SimPump:PumpX-2000:SN-001");
}
/// <summary>
/// ── Measurements with engineering units ─────────────────────
/// All seven analog measurements live under
/// PumpType.Operational.Measurements and are materialised by
/// CreatePumpInstanceAsync via the generator-emitted AddXxx
/// helpers. The cross-namespace name-only resolver fallback
/// means the unqualified browse path resolves through the
/// Pumps -> Machinery (Operational) -> Pumps (Measurements +
/// analog states) namespace transitions transparently.
/// </summary>
/// <param name="builder"></param>
private void WithMeasurements(INodeManagerBuilder builder)
{
AddMeasurement(builder,
"Pump #1/Operational/Measurements/DifferentialPressure",
() => m_currentPressure,
EngineeringUnits.Pascal, min: 0, max: 1_000_000);
AddMeasurement(builder,
"Pump #1/Operational/Measurements/FluidTemperature",
() => m_currentTemperature,
EngineeringUnits.Kelvin, min: 233.15, max: 473.15);
AddMeasurement(builder,
"Pump #1/Operational/Measurements/BearingTemperature",
() => m_currentBearingTemp,
EngineeringUnits.Kelvin, min: 233.15, max: 473.15);
AddMeasurement(builder,
"Pump #1/Operational/Measurements/PumpPowerInput",
() => m_currentPower,
EngineeringUnits.Watt, min: 0, max: 50_000);
AddMeasurement(builder,
"Pump #1/Operational/Measurements/MassFlow",
() => m_currentFlow,
EngineeringUnits.KilogramsPerSecond, min: 0, max: 1.0);
AddMeasurement(builder,
"Pump #1/Operational/Measurements/PumpEfficiency",
() => m_currentEfficiency,
EngineeringUnits.Percent, min: 0, max: 100);
AddMeasurement(builder,
"Pump #1/Operational/Measurements/Level",
() => m_currentLevel,
EngineeringUnits.Metre, min: 0, max: 10);
// Discrete count exposed alongside the analog measurements.
builder.Variable<uint>(
"Pump #1/Operational/Measurements/NumberOfStarts")
.OnRead(() => (uint)Interlocked.Read(ref m_numberOfStarts));
}
private static class EngineeringUnits
{
public static readonly EUInformation Pascal =
new("Pa", "Pascal", "http://www.opcfoundation.org/UA/units/un/cefact");
public static readonly EUInformation Kelvin =
new("K", "Kelvin", "http://www.opcfoundation.org/UA/units/un/cefact");
public static readonly EUInformation Watt =
new("W", "Watt", "http://www.opcfoundation.org/UA/units/un/cefact");
public static readonly EUInformation KilogramsPerSecond =
new("kg/s", "Kilograms per Second", "http://www.opcfoundation.org/UA/units/un/cefact");
public static readonly EUInformation Percent =
new("%", "Percent", "http://www.opcfoundation.org/UA/units/un/cefact");
public static readonly EUInformation Metre =
new("m", "Metre", "http://www.opcfoundation.org/UA/units/un/cefact");
}
/// <summary>
/// ── Supervision flags wired to NAMUR alarms ─────────────────
/// Demonstrates the FB-3 phase 3 typed accessor API: starting
/// from a typed INodeBuilder<PumpState> root, the generator-
/// emitted PumpStateComponents.Events extension walks to
/// SupervisionState (the type of PumpType.Events), and from
/// there the typed SupervisionStateComponents accessor walks
/// to SupervisionProcessFluid and SupervisionPumpOperation —
/// each step is compile-time checked against the model and
/// namespace-aware without forcing the author to spell out
/// browse-paths or QualifiedNames.
/// </summary>
/// <param name="builder"></param>
private void WithSupervision(INodeManagerBuilder builder)
{
ushort pumpsNs = (ushort)Server.NamespaceUris.GetIndex(
Opc.Ua.Pumps.Namespaces.Pumps);
INodeBuilder<PumpState> pump =
builder.Node<PumpState>("Pump #1");
IAlarmBuilder<NonExclusiveLimitAlarmState> tempAlarm = pump
.Components().Events()
.CreateLimitAlarm(new QualifiedName("OverTempAlarm", pumpsNs))
.WithLimits(highHigh: 373.15, high: 363.15, low: 283.15, lowLow: 273.15)
.OnAcknowledge((ctx, c, eventId, comment) => ServiceResult.Good);
pump.Components().Events()
.Components().SupervisionProcessFluid()
.Components().Cavitation()
.OnRead(() => m_cavitation)
.ActivatesAlarm(tempAlarm);
pump.Components().Events()
.Components().SupervisionPumpOperation()
.Components().MotorOverheat()
.OnRead(() => m_motorOverheat);
}
/// <summary>
/// Direct measurement wiring — failures now propagate as
/// BadNodeIdUnknown ServiceResultException so wiring errors
/// surface at configuration time rather than getting silently
/// logged. The legacy TryAdd* helpers and their per-method
/// try/catch blocks were necessary while the optional pump
/// subtree was unmaterialised; CreatePumpInstanceAsync now
/// materialises every wired leaf so the wiring is unconditional.
/// </summary>
/// <param name="builder"></param>
/// <param name="browsePath"></param>
/// <param name="getter"></param>
/// <param name="units"></param>
/// <param name="min"></param>
/// <param name="max"></param>
private static void AddMeasurement(
INodeManagerBuilder builder,
string browsePath,
Func<double> getter,
EUInformation units,
double min,
double max)
{
builder.Variable<double>(browsePath)
.OnRead(getter)
.WithEngineeringUnits(units)
.WithEURange(min, max);
}
/// <summary>
/// ── Simulation tick — advances all live measurements ────────
/// </summary>
private void AdvanceSimulation()
{
long t = Interlocked.Increment(ref m_simulationTicks);
m_currentPressure = 200000.0 + (50000.0 * Math.Sin(t * 0.03));
m_currentTemperature = 313.15 + (5.0 * Math.Sin(t * 0.01));
m_currentBearingTemp = 333.15 + (8.0 * Math.Cos(t * 0.008));
m_currentPower = 5000.0 + (500.0 * Math.Sin(t * 0.02));
m_currentFlow = 0.05 + (0.005 * Math.Cos(t * 0.04));
m_currentEfficiency = 75.0 + (10.0 * Math.Sin(t * 0.015));
m_currentLevel = 2.5 + (0.5 * Math.Sin(t * 0.02));
// Fault injection — supervision flags transition true/false.
m_cavitation = (t % 120) > 100;
m_motorOverheat = (t % 200) > 190;
// Map the simulated supervision flags onto the DI DeviceHealth
// NAMUR NE 107 enumeration. Motor overheat is the more severe
// condition so it wins when both are active. The variable is
// ClearChangeMasks-ed so subscriptions see each transition.
UpdateDeviceHealth();
// Periodic restart simulation — every 3600 ticks (~15 min at 250ms).
if (t % 3600 == 0)
{
Interlocked.Increment(ref m_numberOfStarts);
}
}
/// <summary>
/// Maps the simulated supervision flags onto the DI
/// <see cref="Opc.Ua.Di.DeviceHealthEnumeration"/>
/// using the NAMUR NE 107 severity order: a motor overheat
/// always wins over a cavitation event (FAILURE >
/// MAINTENANCE_REQUIRED); when neither flag is set the device
/// reports NORMAL. Exposed as a pure function so tests can
/// exercise the mapping without instantiating the manager.
/// </summary>
public static Opc.Ua.Di.DeviceHealthEnumeration
MapSupervisionToDeviceHealth(bool cavitation, bool motorOverheat)
{
if (motorOverheat)
{
return Opc.Ua.Di.DeviceHealthEnumeration.FAILURE;
}
if (cavitation)
{
return Opc.Ua.Di.DeviceHealthEnumeration.MAINTENANCE_REQUIRED;
}
return Opc.Ua.Di.DeviceHealthEnumeration.NORMAL;
}
private void UpdateDeviceHealth()
{
BaseDataVariableState<Opc.Ua.Di.DeviceHealthEnumeration>?
health = m_supervisedDeviceHealth;
if (health == null)
{
return;
}
Opc.Ua.Di.DeviceHealthEnumeration desired =
MapSupervisionToDeviceHealth(m_cavitation, m_motorOverheat);
if (health.Value != desired)
{
health.Value = desired;
health.Timestamp = DateTime.UtcNow;
health.ClearChangeMasks(SystemContext, includeChildren: false);
}
}
}
}