Skip to content

Commit 829d8f5

Browse files
Alexsadhana-r
authored andcommitted
Remove override of console temp to 0 (#75)
1 parent 0b526f6 commit 829d8f5

1 file changed

Lines changed: 0 additions & 2 deletions

File tree

notebooks/test_watertank.py

Lines changed: 0 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -165,9 +165,7 @@ def log_temperature():
165165
if not use_external_power_supply:
166166
if prev_con_temp is None:
167167
prev_con_temp = interface.hvcontroller.get_temperature1()
168-
prev_con_temp = 0
169168
con_temp = interface.hvcontroller.get_temperature1()
170-
con_temp = 0
171169
if (con_temp - prev_con_temp) > rapid_temp_increase_per_second_shutoff_C:
172170
logger.warning(f"Console temperature rose from {prev_con_temp}°C to {con_temp}°C (above {rapid_temp_increase_per_second_shutoff_C}°C threshold) within {log_interval}s.")
173171
log_line = f"{current_time},SHUTDOWN,Console temperature exceeded rapid temp increase shutoff threshold\n"

0 commit comments

Comments