Notifications
You must be signed in to change notification settings - Fork 16
udpate api documentation #359
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Merged
Merged
Changes from all commits
Commits
Show all changes
4 commits
Select commit
Hold shift + click to select a range
File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,162 @@ | ||
| **API Documentation** for the High-Level LIFU interface `LIFUInterface` based on | ||
| the contents of `LIFUInterface.py`, `LIFUHVController.py`, and | ||
| `LIFUTXDevice.py`. | ||
|
|
||
| --- | ||
|
|
||
| # `LIFUInterface` API Documentation | ||
|
|
||
| The `LIFUInterface` class provides a high-level interface for managing the LIFU | ||
| system, including the **TX transmitter module** and the **high voltage (HV) | ||
| controller**. It encapsulates all communication and configuration for loading | ||
| ultrasound solutions, performing hardware checks, and controlling sonication | ||
| operations. | ||
|
|
||
| --- | ||
|
|
||
| ## Initialization | ||
|
|
||
| ```python | ||
| interface = LIFUInterface() | ||
| tx_connected, hv_connected = interface.is_device_connected() | ||
|
|
||
| if not tx_connected: | ||
| print("TX device not connected. Attempting to turn on 12V...") | ||
| interface.hvcontroller.turn_12v_on() | ||
|
|
||
| # Give time for the TX device to power up and enumerate over USB | ||
| time.sleep(2) | ||
|
|
||
| # Cleanup and recreate interface to reinitialize USB devices | ||
| interface.stop_monitoring() | ||
| del interface | ||
| time.sleep(1) # Short delay before recreating | ||
|
|
||
| print("Reinitializing LIFU interface after powering 12V...") | ||
| interface = LIFUInterface() | ||
|
|
||
| # Re-check connection | ||
| tx_connected, hv_connected = interface.is_device_connected() | ||
|
|
||
| if tx_connected and hv_connected: | ||
| print("✅ LIFU Device fully connected.") | ||
| else: | ||
| print("❌ LIFU Device NOT fully connected.") | ||
| print(f" TX Connected: {tx_connected}") | ||
| print(f" HV Connected: {hv_connected}") | ||
| sys.exit(1) | ||
| ``` | ||
|
|
||
| --- | ||
|
|
||
| ## Core Components | ||
|
|
||
| - `txdevice`: Instance of `TxDevice` that controls the transmitter module. | ||
| - `hvcontroller`: Instance of `HVController` to control high voltage behavior. | ||
| - `signal_connect`, `signal_disconnect`, `signal_data_received`: Signals emitted | ||
| by the UART layer (if async mode is enabled). | ||
|
|
||
| --- | ||
|
|
||
| ## Key Methods | ||
|
|
||
| ### Device Monitoring | ||
|
|
||
| | Method | Description | | ||
| | --------------------------------------- | ------------------------------------------------------- | | ||
| | `start_monitoring(interval: int = 1)` | Start asynchronous monitoring of USB connection status. | | ||
| | `stop_monitoring()` | Stop USB device monitoring. | | ||
| | `is_device_connected() -> (bool, bool)` | Returns a tuple `(tx_connected, hv_connected)`. | | ||
|
|
||
| --- | ||
|
|
||
| ### Solution Management | ||
|
|
||
| | Method | Description | | ||
| | ----------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------- | | ||
| | `set_solution(solution, profile_index=1, profile_increment=True, trigger_mode="sequence", turn_hv_on=True)` | Load and apply a full ultrasound solution to both TX and HV. | | ||
| | `check_solution(solution)` | Validate the provided solution against voltage and safety limits. | | ||
| | `get_max_voltage(solution)` | Return the safe maximum voltage for a solution. | | ||
| | `get_max_voltage_table()` | Return a Pandas DataFrame showing max voltage per duty cycle and sequence duration. | | ||
| | `get_sequence_duty_cycle(solution)` | Compute the duty cycle from the sequence config. | | ||
| | `get_sequence_duration(solution)` | Compute the total sequence duration from the solution config. | | ||
|
|
||
| --- | ||
|
|
||
| ### Sonication Control | ||
|
|
||
| | Method | Description | | ||
| | -------------------- | ------------------------------------------------- | | ||
| | `start_sonication()` | Powers on HV and starts the pulse trigger for TX. | | ||
| | `stop_sonication()` | Stops TX trigger and powers down HV. | | ||
| | `set_status(status)` | Set the current system status enum. | | ||
| | `get_status()` | Retrieve current internal status enum. | | ||
|
|
||
| --- | ||
|
|
||
| ### Context Manager Support | ||
|
|
||
| ```python | ||
| with LIFUInterface() as interface: | ||
| tx_connected, hv_connected = interface.is_device_connected() | ||
| ... | ||
| ``` | ||
|
|
||
| --- | ||
|
|
||
| ## Status Enum | ||
|
|
||
| The `LIFUInterfaceStatus` enum provides internal state tracking: | ||
|
|
||
| | Status Constant | Meaning | | ||
| | -------------------- | ----------------------- | | ||
| | `STATUS_COMMS_ERROR` | Communication failure | | ||
| | `STATUS_SYS_OFF` | System is off | | ||
| | `STATUS_SYS_POWERUP` | System is powering on | | ||
| | `STATUS_SYS_ON` | System is on | | ||
| | `STATUS_PROGRAMMING` | Programming in progress | | ||
| | `STATUS_READY` | System ready | | ||
| | `STATUS_NOT_READY` | System not ready | | ||
| | `STATUS_RUNNING` | Sonication running | | ||
| | `STATUS_FINISHED` | Sonication finished | | ||
| | `STATUS_ERROR` | System in error state | | ||
|
|
||
| --- | ||
|
|
||
| ## Example: Load and Trigger | ||
|
|
||
| ```python | ||
| from openlifu.plan.solution import Solution | ||
|
|
||
| solution = Solution( | ||
| name="Test", | ||
| voltage=40, | ||
| pulse={"frequency": 2e6, "duration": 2e-6}, | ||
| delays=[0] * 32, | ||
| apodizations=[1] * 32, | ||
| sequence={ | ||
| "pulse_interval": 0.01, | ||
| "pulse_count": 1, | ||
| "pulse_train_interval": 0.0, | ||
| "pulse_train_count": 1, | ||
| }, | ||
| ) | ||
|
|
||
| interface.set_solution(solution) | ||
| interface.start_sonication() | ||
| time.sleep(1) | ||
| interface.stop_sonication() | ||
| ``` | ||
|
|
||
| --- | ||
|
|
||
| ## Notes | ||
|
|
||
| - The TX and HV devices are initialized independently using their respective USB | ||
| VID/PIDs. | ||
| - If devices are disconnected, `turn_12v_on()` can be used to power the TX | ||
| device before retrying connection. | ||
| - Use `check_solution()` to verify safety constraints before applying any | ||
| configuration. | ||
| - `Solution` objects can be converted to `dict` automatically by | ||
| `LIFUInterface`. |
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Uh oh!
There was an error while loading. Please reload this page.