Notifications
You must be signed in to change notification settings - Fork 10
Expand file tree
/
Copy pathrectifier.py
More file actions
207 lines (182 loc) · 9.26 KB
/
Copy pathrectifier.py
File metadata and controls
207 lines (182 loc) · 9.26 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
import sys
import can
import struct
import subprocess
import time
import argparse
# CAN stuff
ARBITRATION_ID = 0x0607FF83 # or 06080783 ?
ARBITRATION_ID_READ = 0x06000783
BITRATE = 125000
# individual properties to read out, data: 0x01, 0xF0, 0x00, p, 0x00, 0x00, 0x00, 0x00 with p:
# 01 : output voltage
# 02 : output current
# 03 : output current limit
# 04 : temperature in C
# 05 : supply voltage
READ_COMMANDS = [0x01, 0x02, 0x03, 0x04, 0x05]
# Reads all of the above and a few more at once
READ_ALL = [0x00, 0xF0, 0x00, 0x80, 0x46, 0xA5, 0x34, 0x00]
# 62.5A is the nominal current of Emerson/Vertiv R48-3000e and corresponds to 121%
OUTPUT_CURRENT_RATED_VALUE = 62.5
OUTPUT_CURRENT_RATED_PERCENTAGE_MIN = 10
OUTPUT_CURRENT_RATED_PERCENTAGE_MAX = 121
OUTPUT_VOLTAGE_MIN = 41.0
OUTPUT_VOLTAGE_MAX = 58.5
OUTPUT_CURRENT_MIN = 5.5
OUTPUT_CURRENT_MAX = OUTPUT_CURRENT_RATED_VALUE
# Helper Functions
# Needs root/sudo access, or configure this part on the OS
def config(channel):
"""Configure the CAN interface."""
try:
subprocess.run(['ip', 'link', 'set', 'down', channel], check=True)
subprocess.run(['ip', 'link', 'set', channel, 'type', 'can', 'bitrate', str(BITRATE), 'restart-ms', '1500'], check=True)
subprocess.run(['ip', 'link', 'set', 'up', channel], check=True)
print(f"Configured CAN interface: {channel}")
except subprocess.CalledProcessError as e:
print(f"Failed to configure CAN interface {channel}: {e}")
# Converts a few possible strings to boolean
def str_to_bool(value):
"""Parse string to boolean (case-insensitive)."""
if isinstance(value, bool):
return value
if value.lower() in {'true', 't', 'yes', '1'}:
return True
elif value.lower() in {'false', 'f', 'no', '0'}:
return False
else:
raise argparse.ArgumentTypeError(f"Invalid boolean value: {value}")
# To convert floating point units to 4 bytes in a bytearray
def float_to_bytearray(f):
"""Convert a float to a 4-byte array."""
return bytearray(struct.pack('<f', f))
# Check if options passed are within accepted range
def validate_range(value, min_val, max_val, name):
"""Validate that a value is within the specified range."""
if not (min_val <= value <= max_val):
raise ValueError(f"{name} must be between {min_val} and {max_val}. Got {value}.")
return value
# Get the bus and send data to the specified CAN bus
def send_can_message(channel, data):
"""Send a message to the CAN bus."""
try:
with can.interface.Bus(bustype='socketcan', channel=channel, bitrate=BITRATE) as bus:
msg = can.Message(arbitration_id=ARBITRATION_ID, data=data, is_extended_id=True)
bus.send(msg)
print(f"Command sent on {bus.channel_info}")
except can.CanError as e:
print(f"CAN message send error: {e}")
# CAN message receiver
def receive_can_message(channel):
"""Receive and print messages from the CAN bus."""
try:
with can.interface.Bus(receive_own_messages=True, bustype='socketcan', channel=channel, bitrate=BITRATE) as bus:
#print_listener = can.Printer()
#can.Notifier(bus, [print_listener])
can.Notifier(bus, [can_listener])
# Keep sending requests for all data every second
while True:
# Individually
#for p in READ_COMMANDS:
# data = [0x01, 0xF0, 0x00, p, 0x00, 0x00, 0x00, 0x00]
# msg = can.Message(arbitration_id=ARBITRATION_ID_READ, data=data, is_extended_id=True)
# bus.send(msg)
# time.sleep(0.1)
# All at once
msg = can.Message(arbitration_id=ARBITRATION_ID_READ, data=READ_ALL, is_extended_id=True)
bus.send(msg)
time.sleep(1.0)
except can.CanError as e:
print(f"CAN message receive error: {e}")
# CAN receiver listener
def can_listener(msg):
"""Process received CAN messages."""
# Is it a response to our request
if msg.data[0] == 0x41:
# Convert value to float (it's the same for all)
val = struct.unpack('>f', msg.data[4:8])[0]
# Check what data it is
match msg.data[3]:
case 0x01: print(f"Vout (VDC): {val}")
case 0x02: print(f"Iout (IDC): {val}")
case 0x03: print(f"Output Current Limit: {val}")
case 0x04: print(f"Temp (°C): {val}")
case 0x05: print(f"Vin (VAC): {val}")
# Set the output voltage to the new value.
# The 'fixed' parameter
# - if True makes the change permanent ('offline command')
# - if False the change is temporary (30 seconds per command received, 'online command', repeat at 15 second intervals).
# Voltage between 41.0 and 58.5V - fan will go high below 48V!
def set_voltage(channel, voltage, fixed=False):
"""Set output voltage."""
validate_range(voltage, OUTPUT_VOLTAGE_MIN, OUTPUT_VOLTAGE_MAX, "Voltage")
cmd = 0x24 if fixed else 0x21
send_can_message(channel, [0x03, 0xF0, 0x00, cmd, *float_to_bytearray(voltage)])
# The output current is set in percent to the rated value of the rectifier written in the manual
# Possible values for 'current': 10% - 121% (rated current in the datasheet = 121%)
# The 'fixed' parameter
# - if True makes the change permanent ('offline command')
# - if False the change is temporary (30 seconds per command received, 'online command', repeat at 15 second intervals)
def set_current_percentage(channel, percent, fixed=False):
"""Set output current as a percentage."""
validate_range(percent, OUTPUT_CURRENT_RATED_PERCENTAGE_MIN, OUTPUT_CURRENT_RATED_PERCENTAGE_MAX, "Current percentage")
cmd = 0x19 if fixed else 0x22
send_can_message(channel, [0x03, 0xF0, 0x00, cmd, *float_to_bytearray(percent / 100)])
# The output current is set as a value
# Possible values for 'current': 5.5A - 62.5A
# The 'fixed' parameter
# - if True makes the change permanent ('offline command')
# - if False the change is temporary (30 seconds per command received, 'online command', repeat at 15 second intervals).
def set_current_value(channel, current, fixed=False):
"""Set output current in amps."""
validate_range(current, OUTPUT_CURRENT_MIN, OUTPUT_CURRENT_MAX, "Current")
percent = (current / OUTPUT_CURRENT_RATED_VALUE) * OUTPUT_CURRENT_RATED_PERCENTAGE_MAX
set_current_percentage(channel, percent, fixed)
# Time to ramp up the rectifiers output voltage to the set voltage value, and enable/disable
def walk_in(channel, time=0, enable=False):
"""Enable or disable walk-in functionality."""
data = [0x03, 0xF0, 0x00, 0x32, 0x00, 0x01 if enable else 0x00, 0x00, 0x00]
if enable:
data.extend(float_to_bytearray(time))
send_can_message(channel, data)
# AC input current limit (called Diesel power limit): gives the possibility to reduce the overall power of the rectifier
def limit_input(channel, current):
"""Set AC input current limit."""
send_can_message(channel, [0x03, 0xF0, 0x00, 0x1A, *float_to_bytearray(current)])
# Restart after overvoltage enable/disable
def restart_overvoltage(channel, state=False):
"""Enable or disable restart after overvoltage."""
send_can_message(channel, [0x03, 0xF0, 0x00, 0x39, 0x00, 0x01 if state else 0x00, 0x00, 0x00])
# Main
if __name__ == "__main__":
parser = argparse.ArgumentParser(description="Control Emerson/Vertiv Rectifiers via CAN.")
parser.add_argument("-m", "--mode", choices=["set", "get"], help="Operation mode: set or get")
parser.add_argument("-v", "--voltage", type=float, help="Set output voltage (41.0V - 58.5V)")
parser.add_argument("-cv", "--current_value", type=float, help="Set output current in amps (5.5A - 62.5A)")
parser.add_argument("-cp", "--current_percent", type=float, help="Set output current as percentage (10%% - 121%%)")
parser.add_argument("-p", "--permanent", action="store_true", help="Make settings permanent")
parser.add_argument("-I", "--interface", default="can0", help="CAN interface (default: can0)")
parser.add_argument("-C", "--configure", action="store_true", help="Configure CAN interface")
parser.add_argument("--walk_in", type=str_to_bool, help="Enable or disable walk-in")
parser.add_argument("--walk_in_time", type=float, help="Walk-in ramp-up time (seconds)")
parser.add_argument("--limit_input", type=float, help="Set AC input current limit (amps)")
parser.add_argument("--restart_overvoltage", type=str_to_bool, help="Enable or disable restart after overvoltage")
args = parser.parse_args()
if args.configure:
config(args.interface)
if args.mode == "set":
if args.voltage:
set_voltage(args.interface, args.voltage, args.permanent)
if args.current_value:
set_current_value(args.interface, args.current_value, args.permanent)
if args.current_percent:
set_current_percentage(args.interface, args.current_percent, args.permanent)
if args.walk_in is not None:
walk_in(args.interface, time=args.walk_in_time or 0, enable=args.walk_in)
if args.limit_input:
limit_input(args.interface, args.limit_input)
if args.restart_overvoltage is not None:
restart_overvoltage(args.interface, state=args.restart_overvoltage)
elif args.mode == "get":
receive_can_message(args.interface)