@@ -16,6 +16,9 @@ Upcoming Release
16
16
.. The features listed below are not released yet, but will be part of the next release!
17
17
.. To use the features already you have to use the ``master`` branch.
18
18
19
+
* Breaking changes:
20
+
- Renamed "electricity grid connection" to "distribution grid reinforcement" and updated description for more clarity on the technology and consistency with the source.
21
+
19
22
* Add missing discount rate for OCGT in US-specific data. (https://github.com/PyPSA/technology-data/pull/269)
20
23
21
24
`v0.14.0 <https://github.com/PyPSA/technology-data/releases/tag/v0.14.0>`__ (13th February 2026)
distribution grid reinforcement,investment,2025,150,EUR/kW,2020,DEA - Technology Data Catalogue for el and DH - v17 - Page 15 - Paragraph 'Cost of grid expansion',"The costs of grid expansion from adding a new electricity generator or a new large consumer - related to strengthening or expansion of the local grid and/or substations (voltage transformation, pumping or compression/expansion)"
3
+
distribution grid reinforcement,lifetime,2025,40,years,2020,same as 'electricity distribution grid',
4
+
distribution grid reinforcement,FOM,2025,2,%/year,2020,same as 'electricity distribution grid',
2
5
methanation,investment,2020,748,EUR/kW_CH4,2017,"Agora Energiewende (2018): The Future Cost of Electricity-Based Synthetic Fuels (https://www.agora-energiewende.de/en/publications/the-future-cost-of-electricity-based-synthetic-fuels-1/), table 6: “Reference scenario”.",
3
6
methanation,lifetime,2020,20,years,2017,Guesstimate.,"Based on lifetime for methanolisation, Fischer-Tropsch plants."
4
7
methanation,FOM,2020,3,%/year,2017,"Agora Energiewende (2018): The Future Cost of Electricity-Based Synthetic Fuels (https://www.agora-energiewende.de/en/publications/the-future-cost-of-electricity-based-synthetic-fuels-1/), section 6.2.3.1",
Copy file name to clipboardExpand all lines: outputs/US/costs_2020.csv
+3-3Lines changed: 3 additions & 3 deletions
Original file line number
Diff line number
Diff line change
@@ -3920,6 +3920,9 @@ direct firing solid fuels CC,VOM,0.4119,EUR/MWh,"Danish Energy Agency, inputs/te
3920
3920
direct firing solid fuels CC,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx","312.b Direct firing Sold Fuels: Total efficiency, net, annual average",2019.0,,
3921
3921
direct firing solid fuels CC,investment,278.5499,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",312.b Direct firing Sold Fuels: Nominal investment,2019.0,,
3922
3922
direct firing solid fuels CC,lifetime,15.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",312.b Direct firing Sold Fuels: Technical lifetime,2019.0,,
3923
+
distribution grid reinforcement,FOM,2.0,%/year,same as 'electricity distribution grid',,2020.0,,
3924
+
distribution grid reinforcement,investment,188.6002,EUR/kW,DEA - Technology Data Catalogue for el and DH - v17 - Page 15 - Paragraph 'Cost of grid expansion',"The costs of grid expansion from adding a new electricity generator or a new large consumer - related to strengthening or expansion of the local grid and/or substations (voltage transformation, pumping or compression/expansion)",2020.0,,
3925
+
distribution grid reinforcement,lifetime,40.0,years,same as 'electricity distribution grid',,2020.0,,
3923
3926
dry bulk carrier Capesize,FOM,4.0,%/year,"Based on https://www.hellenicshippingnews.com/capesize-freight-returns-below-operating-expense-levels-but-shipowners-reject-lay-ups/, accessed: 2022-12-03.","5000 USD/d OPEX, exchange rate: 1.15 USD = 1 EUR; absolute value calculate relative to investment cost.",2020.0,,
3924
3927
dry bulk carrier Capesize,capacity,180000.0,t,-,"DWT; corresponds to size of Capesize bulk carriers which have previously docked at the habour in Hamburg, Germany. Short of 200 kt limit for VLBCs.",2020.0,,
3925
3928
dry bulk carrier Capesize,investment,50293384.0456,EUR,"Based on https://www.hellenicshippingnews.com/dry-bulk-carriers-in-high-demand-as-rates-keep-rallying/, accessed: 2022-12-03.","See figure for ‘Dry Bulk Newbuild Prices’, Capesize at end of 2020. Exchange rate: 1.15 USD = 1 EUR.",2020.0,,
@@ -3952,9 +3955,6 @@ electric steam cracker,naphtha-input,14.8,MWh_naphtha/t_HVC,"Lechtenböhmer et a
3952
3955
electricity distribution grid,FOM,2.0,%/year,TODO, from old pypsa cost assumptions,2015.0,,
3953
3956
electricity distribution grid,investment,667.9016,EUR/kW,TODO, from old pypsa cost assumptions,2015.0,,
3954
3957
electricity distribution grid,lifetime,40.0,years,TODO, from old pypsa cost assumptions,2015.0,,
3955
-
electricity grid connection,FOM,2.0,%/year,TODO, from old pypsa cost assumptions,2015.0,,
3956
-
electricity grid connection,investment,187.0124,EUR/kW,DEA, from old pypsa cost assumptions,2015.0,,
3957
-
electricity grid connection,lifetime,40.0,years,TODO, from old pypsa cost assumptions,2015.0,,
3958
3958
electrobiofuels,C in fuel,0.9245,per unit,Stoichiometric calculation,,,,
3959
3959
electrobiofuels,FOM,2.4,%/year,combination of BtL and electrofuels,,2015.0,,
3960
3960
electrobiofuels,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2025.csv
+3-3Lines changed: 3 additions & 3 deletions
Original file line number
Diff line number
Diff line change
@@ -4006,6 +4006,9 @@ direct firing solid fuels CC,VOM,0.415,EUR/MWh,"Danish Energy Agency, inputs/tec
4006
4006
direct firing solid fuels CC,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx","312.b Direct firing Sold Fuels: Total efficiency, net, annual average",2019.0,,
4007
4007
direct firing solid fuels CC,investment,278.5499,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",312.b Direct firing Sold Fuels: Nominal investment,2019.0,,
4008
4008
direct firing solid fuels CC,lifetime,15.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",312.b Direct firing Sold Fuels: Technical lifetime,2019.0,,
4009
+
distribution grid reinforcement,FOM,2.0,%/year,same as 'electricity distribution grid',,2020.0,,
4010
+
distribution grid reinforcement,investment,188.6002,EUR/kW,DEA - Technology Data Catalogue for el and DH - v17 - Page 15 - Paragraph 'Cost of grid expansion',"The costs of grid expansion from adding a new electricity generator or a new large consumer - related to strengthening or expansion of the local grid and/or substations (voltage transformation, pumping or compression/expansion)",2020.0,,
4011
+
distribution grid reinforcement,lifetime,40.0,years,same as 'electricity distribution grid',,2020.0,,
4009
4012
dry bulk carrier Capesize,FOM,4.0,%/year,"Based on https://www.hellenicshippingnews.com/capesize-freight-returns-below-operating-expense-levels-but-shipowners-reject-lay-ups/, accessed: 2022-12-03.","5000 USD/d OPEX, exchange rate: 1.15 USD = 1 EUR; absolute value calculate relative to investment cost.",2020.0,,
4010
4013
dry bulk carrier Capesize,capacity,180000.0,t,-,"DWT; corresponds to size of Capesize bulk carriers which have previously docked at the habour in Hamburg, Germany. Short of 200 kt limit for VLBCs.",2020.0,,
4011
4014
dry bulk carrier Capesize,investment,50293384.0456,EUR,"Based on https://www.hellenicshippingnews.com/dry-bulk-carriers-in-high-demand-as-rates-keep-rallying/, accessed: 2022-12-03.","See figure for ‘Dry Bulk Newbuild Prices’, Capesize at end of 2020. Exchange rate: 1.15 USD = 1 EUR.",2020.0,,
@@ -4038,9 +4041,6 @@ electric steam cracker,naphtha-input,14.8,MWh_naphtha/t_HVC,"Lechtenböhmer et a
4038
4041
electricity distribution grid,FOM,2.0,%/year,TODO, from old pypsa cost assumptions,2015.0,,
4039
4042
electricity distribution grid,investment,667.9016,EUR/kW,TODO, from old pypsa cost assumptions,2015.0,,
4040
4043
electricity distribution grid,lifetime,40.0,years,TODO, from old pypsa cost assumptions,2015.0,,
4041
-
electricity grid connection,FOM,2.0,%/year,TODO, from old pypsa cost assumptions,2015.0,,
4042
-
electricity grid connection,investment,187.0124,EUR/kW,DEA, from old pypsa cost assumptions,2015.0,,
4043
-
electricity grid connection,lifetime,40.0,years,TODO, from old pypsa cost assumptions,2015.0,,
4044
4044
electrobiofuels,C in fuel,0.9257,per unit,Stoichiometric calculation,,,,
4045
4045
electrobiofuels,FOM,2.5263,%/year,combination of BtL and electrofuels,,2015.0,,
4046
4046
electrobiofuels,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2030.csv
+3-3Lines changed: 3 additions & 3 deletions
Original file line number
Diff line number
Diff line change
@@ -4162,6 +4162,9 @@ direct firing solid fuels CC,VOM,0.4182,EUR/MWh,"Danish Energy Agency, inputs/te
4162
4162
direct firing solid fuels CC,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx","312.b Direct firing Sold Fuels: Total efficiency, net, annual average",2019.0,,
4163
4163
direct firing solid fuels CC,investment,278.5499,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",312.b Direct firing Sold Fuels: Nominal investment,2019.0,,
4164
4164
direct firing solid fuels CC,lifetime,15.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",312.b Direct firing Sold Fuels: Technical lifetime,2019.0,,
4165
+
distribution grid reinforcement,FOM,2.0,%/year,same as 'electricity distribution grid',,2020.0,,
4166
+
distribution grid reinforcement,investment,188.6002,EUR/kW,DEA - Technology Data Catalogue for el and DH - v17 - Page 15 - Paragraph 'Cost of grid expansion',"The costs of grid expansion from adding a new electricity generator or a new large consumer - related to strengthening or expansion of the local grid and/or substations (voltage transformation, pumping or compression/expansion)",2020.0,,
4167
+
distribution grid reinforcement,lifetime,40.0,years,same as 'electricity distribution grid',,2020.0,,
4165
4168
dry bulk carrier Capesize,FOM,4.0,%/year,"Based on https://www.hellenicshippingnews.com/capesize-freight-returns-below-operating-expense-levels-but-shipowners-reject-lay-ups/, accessed: 2022-12-03.","5000 USD/d OPEX, exchange rate: 1.15 USD = 1 EUR; absolute value calculate relative to investment cost.",2020.0,,
4166
4169
dry bulk carrier Capesize,capacity,180000.0,t,-,"DWT; corresponds to size of Capesize bulk carriers which have previously docked at the habour in Hamburg, Germany. Short of 200 kt limit for VLBCs.",2020.0,,
4167
4170
dry bulk carrier Capesize,investment,50293384.0456,EUR,"Based on https://www.hellenicshippingnews.com/dry-bulk-carriers-in-high-demand-as-rates-keep-rallying/, accessed: 2022-12-03.","See figure for ‘Dry Bulk Newbuild Prices’, Capesize at end of 2020. Exchange rate: 1.15 USD = 1 EUR.",2020.0,,
@@ -4194,9 +4197,6 @@ electric steam cracker,naphtha-input,14.8,MWh_naphtha/t_HVC,"Lechtenböhmer et a
4194
4197
electricity distribution grid,FOM,2.0,%/year,TODO, from old pypsa cost assumptions,2015.0,,
4195
4198
electricity distribution grid,investment,667.9016,EUR/kW,TODO, from old pypsa cost assumptions,2015.0,,
4196
4199
electricity distribution grid,lifetime,40.0,years,TODO, from old pypsa cost assumptions,2015.0,,
4197
-
electricity grid connection,FOM,2.0,%/year,TODO, from old pypsa cost assumptions,2015.0,,
4198
-
electricity grid connection,investment,187.0124,EUR/kW,DEA, from old pypsa cost assumptions,2015.0,,
4199
-
electricity grid connection,lifetime,40.0,years,TODO, from old pypsa cost assumptions,2015.0,,
4200
4200
electrobiofuels,C in fuel,0.9269,per unit,Stoichiometric calculation,,,,
4201
4201
electrobiofuels,FOM,2.6667,%/year,combination of BtL and electrofuels,,2015.0,,
4202
4202
electrobiofuels,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2035.csv
+3-3Lines changed: 3 additions & 3 deletions
Original file line number
Diff line number
Diff line change
@@ -4186,6 +4186,9 @@ direct firing solid fuels CC,VOM,0.4198,EUR/MWh,"Danish Energy Agency, inputs/te
4186
4186
direct firing solid fuels CC,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx","312.b Direct firing Sold Fuels: Total efficiency, net, annual average",2019.0,,
4187
4187
direct firing solid fuels CC,investment,278.5499,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",312.b Direct firing Sold Fuels: Nominal investment,2019.0,,
4188
4188
direct firing solid fuels CC,lifetime,15.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",312.b Direct firing Sold Fuels: Technical lifetime,2019.0,,
4189
+
distribution grid reinforcement,FOM,2.0,%/year,same as 'electricity distribution grid',,2020.0,,
4190
+
distribution grid reinforcement,investment,188.6002,EUR/kW,DEA - Technology Data Catalogue for el and DH - v17 - Page 15 - Paragraph 'Cost of grid expansion',"The costs of grid expansion from adding a new electricity generator or a new large consumer - related to strengthening or expansion of the local grid and/or substations (voltage transformation, pumping or compression/expansion)",2020.0,,
4191
+
distribution grid reinforcement,lifetime,40.0,years,same as 'electricity distribution grid',,2020.0,,
4189
4192
dry bulk carrier Capesize,FOM,4.0,%/year,"Based on https://www.hellenicshippingnews.com/capesize-freight-returns-below-operating-expense-levels-but-shipowners-reject-lay-ups/, accessed: 2022-12-03.","5000 USD/d OPEX, exchange rate: 1.15 USD = 1 EUR; absolute value calculate relative to investment cost.",2020.0,,
4190
4193
dry bulk carrier Capesize,capacity,180000.0,t,-,"DWT; corresponds to size of Capesize bulk carriers which have previously docked at the habour in Hamburg, Germany. Short of 200 kt limit for VLBCs.",2020.0,,
4191
4194
dry bulk carrier Capesize,investment,50293384.0456,EUR,"Based on https://www.hellenicshippingnews.com/dry-bulk-carriers-in-high-demand-as-rates-keep-rallying/, accessed: 2022-12-03.","See figure for ‘Dry Bulk Newbuild Prices’, Capesize at end of 2020. Exchange rate: 1.15 USD = 1 EUR.",2020.0,,
@@ -4218,9 +4221,6 @@ electric steam cracker,naphtha-input,14.8,MWh_naphtha/t_HVC,"Lechtenböhmer et a
4218
4221
electricity distribution grid,FOM,2.0,%/year,TODO, from old pypsa cost assumptions,2015.0,,
4219
4222
electricity distribution grid,investment,667.9016,EUR/kW,TODO, from old pypsa cost assumptions,2015.0,,
4220
4223
electricity distribution grid,lifetime,40.0,years,TODO, from old pypsa cost assumptions,2015.0,,
4221
-
electricity grid connection,FOM,2.0,%/year,TODO, from old pypsa cost assumptions,2015.0,,
4222
-
electricity grid connection,investment,187.0124,EUR/kW,DEA, from old pypsa cost assumptions,2015.0,,
4223
-
electricity grid connection,lifetime,40.0,years,TODO, from old pypsa cost assumptions,2015.0,,
4224
4224
electrobiofuels,C in fuel,0.9281,per unit,Stoichiometric calculation,,,,
4225
4225
electrobiofuels,FOM,2.7484,%/year,combination of BtL and electrofuels,,2015.0,,
4226
4226
electrobiofuels,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,,,
Copy file name to clipboardExpand all lines: outputs/US/costs_2040.csv
+3-3Lines changed: 3 additions & 3 deletions
Original file line number
Diff line number
Diff line change
@@ -4186,6 +4186,9 @@ direct firing solid fuels CC,VOM,0.4214,EUR/MWh,"Danish Energy Agency, inputs/te
4186
4186
direct firing solid fuels CC,efficiency,1.0,per unit,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx","312.b Direct firing Sold Fuels: Total efficiency, net, annual average",2019.0,,
4187
4187
direct firing solid fuels CC,investment,278.5499,EUR/kW,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",312.b Direct firing Sold Fuels: Nominal investment,2019.0,,
4188
4188
direct firing solid fuels CC,lifetime,15.0,years,"Danish Energy Agency, inputs/technology_data_for_industrial_process_heat.xlsx",312.b Direct firing Sold Fuels: Technical lifetime,2019.0,,
4189
+
distribution grid reinforcement,FOM,2.0,%/year,same as 'electricity distribution grid',,2020.0,,
4190
+
distribution grid reinforcement,investment,188.6002,EUR/kW,DEA - Technology Data Catalogue for el and DH - v17 - Page 15 - Paragraph 'Cost of grid expansion',"The costs of grid expansion from adding a new electricity generator or a new large consumer - related to strengthening or expansion of the local grid and/or substations (voltage transformation, pumping or compression/expansion)",2020.0,,
4191
+
distribution grid reinforcement,lifetime,40.0,years,same as 'electricity distribution grid',,2020.0,,
4189
4192
dry bulk carrier Capesize,FOM,4.0,%/year,"Based on https://www.hellenicshippingnews.com/capesize-freight-returns-below-operating-expense-levels-but-shipowners-reject-lay-ups/, accessed: 2022-12-03.","5000 USD/d OPEX, exchange rate: 1.15 USD = 1 EUR; absolute value calculate relative to investment cost.",2020.0,,
4190
4193
dry bulk carrier Capesize,capacity,180000.0,t,-,"DWT; corresponds to size of Capesize bulk carriers which have previously docked at the habour in Hamburg, Germany. Short of 200 kt limit for VLBCs.",2020.0,,
4191
4194
dry bulk carrier Capesize,investment,50293384.0456,EUR,"Based on https://www.hellenicshippingnews.com/dry-bulk-carriers-in-high-demand-as-rates-keep-rallying/, accessed: 2022-12-03.","See figure for ‘Dry Bulk Newbuild Prices’, Capesize at end of 2020. Exchange rate: 1.15 USD = 1 EUR.",2020.0,,
@@ -4218,9 +4221,6 @@ electric steam cracker,naphtha-input,14.8,MWh_naphtha/t_HVC,"Lechtenböhmer et a
4218
4221
electricity distribution grid,FOM,2.0,%/year,TODO, from old pypsa cost assumptions,2015.0,,
4219
4222
electricity distribution grid,investment,667.9016,EUR/kW,TODO, from old pypsa cost assumptions,2015.0,,
4220
4223
electricity distribution grid,lifetime,40.0,years,TODO, from old pypsa cost assumptions,2015.0,,
4221
-
electricity grid connection,FOM,2.0,%/year,TODO, from old pypsa cost assumptions,2015.0,,
4222
-
electricity grid connection,investment,187.0124,EUR/kW,DEA, from old pypsa cost assumptions,2015.0,,
4223
-
electricity grid connection,lifetime,40.0,years,TODO, from old pypsa cost assumptions,2015.0,,
4224
4224
electrobiofuels,C in fuel,0.9292,per unit,Stoichiometric calculation,,,,
4225
4225
electrobiofuels,FOM,2.8364,%/year,combination of BtL and electrofuels,,2015.0,,
4226
4226
electrobiofuels,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,,,