<?xml version="1.0" encoding="UTF-8"?>
<imager xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema">
<serial>0</serial> <!-- Provide serial number, if you attach more than one camera -->
<videoformatindex>0</videoformatindex> <!-- index of the used video format resolution and framerate (USB enpoint): http://documentation.evocortex.com/libirimager2/html/index.html#sec_videoformat -->
<formatspath>.\</formatspath>
<!-- <calipath></calipath> -->
<!-- Uncomment the following lines to specify user-defined parameters for the desired optic
and temperature range. Be aware to specify meaningful parameters.
See documentation for further information: http://documentation.evocortex.com/libirimager2/html/index.html
By default, the first available optic and the first meaningful temperature range are selected.
fov: If the camera is calibrated for multiple optics with different field of views, the fiel of view of the used optic needs to be set here.
optics_text: If the camera is calibrated for multiple optics with the same field of view, the additional name of the optic need to be set here.
temperature: This value specify the selection of the calibration temperature range.
Only predefined temperature ranges are valid which can be obtained through the data sheet of your camera or PIX Connect.
-->
<!--
<fov>0</fov>
<temperature>
<min>-20</min>
<max>100</max>
</temperature>
<optics_text></optics_text>
-->
<framerate>32.0</framerate> <!-- only scaled down frame rate, maximum framerate depends on the chosen <videoformatindex> -->
<bispectral>0</bispectral> <!-- 0=only thermal sensor, 1=bispectral technology (only PI200/PI230) -->
<autoflag>
<enable>1</enable> <!-- 0=Off, 1=On; Enables automatic flag cycle depending on internal camera temperature or time-->
<mininterval>15.0</mininterval> <!-- Minimum duration in seconds between flag cycle-->
<maxinterval>0.0</maxinterval> <!-- Maximum duration in seconds between flag cycle. Set to 0 to disable.-->
</autoflag>
<tchipmode>0</tchipmode> <!-- 0=Floating (default), 1=Auto, 2=Fixed value -->
<tchipfixedvalue>40.0</tchipfixedvalue> <!-- Fixed value for tchipmode=2 -->
<focus>-1</focus> <!-- position of focus motor in % of range [0; 100]; Set to negative value to disable focus change on startup -->
<enable_extended_temp_range>0</enable_extended_temp_range> <!-- 0=Off, 1=On; Caution! Enables invalid extended temp range-->
<buffer_queue_size>5</buffer_queue_size> <!-- internal buffer queue size -->
<enable_high_precision>0</enable_high_precision> <!-- 0=Off, 1=On; Enables temperatures with more than 1 decimal places. Depends on used camera(IRImager::getTemprangeDecimal()).-->
<radial_distortion_correction>0</radial_distortion_correction> <!-- Distortion correction: 0=Off, 1=Normal, 2=Wide -->
<use_external_probe>0</use_external_probe> <!-- 0=Off, 1=On; Temperatures values of external probe BR20AR are accessible on PIFs first analog input in °C-->
<!--
Uncomment the following lines to connect to a ethernet capable camera device e.g. Xi80 or Xi410
<device_api> Must be set to 5 for ethernet device api
<device_ip_address> IP-Address of the camera
<local_udp_port> Local UDP port on which the camera sends data to (can be configured through PIX Connect)
<check_udp_sender_ip> 0=Off, 1=On; If on, checks the sender ip address of the received data to be equal to the configured camera ip address.
-->
<!--
<device_api>5</device_api>
<ethernet_device>
<device_ip_address>192.168.0.11</device_ip_address>
<local_udp_port>50011</local_udp_port>
<check_udp_sender_ip>1</check_udp_sender_ip>
</ethernet_device>
-->
</imager>