Description

Hi
I added 2 endpoint device which is having metering command class and reporting while adding

For EP0
2025-07-24T10:52:45+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/Metering/Attributes/ClusterRevision/Desired {"value": 1}
2025-07-24T10:52:45+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/Metering/Attributes/ClusterRevision/Reported {"value": 1}
2025-07-24T10:52:45+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/Metering/Attributes/MeteringDeviceType/Desired {"value":"ElectricMetering"}
2025-07-24T10:52:45+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/Metering/Attributes/MeteringDeviceType/Reported {"value":"ElectricMetering"}
2025-07-24T10:52:45+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/Metering/Attributes/UnitofMeasure/Desired {"value":"KilowattHoursOrKilowatts"}
2025-07-24T10:52:45+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/Metering/Attributes/UnitofMeasure/Reported {"value":"KilowattHoursOrKilowatts"}
2025-07-24T10:52:46+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/Metering/Attributes/CurrentSummationDelivered/Desired {"value":0}
2025-07-24T10:52:46+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/Metering/Attributes/CurrentSummationDelivered/Reported {"value":0}

2025-07-24T10:52:46+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/ClusterRevision/Desired {"value": 2}
2025-07-24T10:52:46+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/ClusterRevision/Reported {"value": 2}
2025-07-24T10:52:46+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/ActivePower/Desired {"value":0}
2025-07-24T10:52:46+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/ActivePower/Reported {"value":0}
2025-07-24T10:52:46+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/RMSVoltage/Desired {"value":239}
2025-07-24T10:52:46+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/RMSVoltage/Reported {"value":239}
2025-07-24T10:52:46+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/RMSCurrent/Desired {"value":0}
2025-07-24T10:52:46+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/RMSCurrent/Reported {"value":0}

For EP1
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/Metering/Attributes/ClusterRevision/Desired {"value": 1}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/Metering/Attributes/ClusterRevision/Reported {"value": 1}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/Metering/Attributes/MeteringDeviceType/Desired {"value":"ElectricMetering"}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/Metering/Attributes/MeteringDeviceType/Reported {"value":"ElectricMetering"}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/Metering/Attributes/UnitofMeasure/Desired {"value":"KilowattHoursOrKilowatts"}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/Metering/Attributes/UnitofMeasure/Reported {"value":"KilowattHoursOrKilowatts"}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/Metering/Attributes/CurrentSummationDelivered/Desired {"value":0}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/Metering/Attributes/CurrentSummationDelivered/Reported {"value":0}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/ElectricalMeasurement/Attributes/ClusterRevision/Desired {"value": 2}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/ElectricalMeasurement/Attributes/ClusterRevision/Reported {"value": 2}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/ElectricalMeasurement/Attributes/ActivePower/Desired {"value":0}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/ElectricalMeasurement/Attributes/ActivePower/Reported {"value":0}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/ElectricalMeasurement/Attributes/RMSVoltage/Desired {"value":239}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/ElectricalMeasurement/Attributes/RMSVoltage/Reported {"value":239}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/ElectricalMeasurement/Attributes/RMSCurrent/Desired {"value":0}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/ElectricalMeasurement/Attributes/RMSCurrent/Reported {"value":0}

For EP2
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/Metering/Attributes/ClusterRevision/Desired {"value": 1}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/Metering/Attributes/ClusterRevision/Reported {"value": 1}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/Metering/Attributes/MeteringDeviceType/Desired {"value":"ElectricMetering"}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/Metering/Attributes/MeteringDeviceType/Reported {"value":"ElectricMetering"}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/Metering/Attributes/UnitofMeasure/Desired {"value":"KilowattHoursOrKilowatts"}
2025-07-24T10:53:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/Metering/Attributes/UnitofMeasure/Reported {"value":"KilowattHoursOrKilowatts"}
2025-07-24T10:53:17+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/Metering/Attributes/CurrentSummationDelivered/Desired {"value":0}
2025-07-24T10:53:17+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/Metering/Attributes/CurrentSummationDelivered/Reported {"value":0}
2025-07-24T10:53:17+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/ElectricalMeasurement/Attributes/ClusterRevision/Desired {"value": 2}
2025-07-24T10:53:17+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/ElectricalMeasurement/Attributes/ClusterRevision/Reported {"value": 2}
2025-07-24T10:53:17+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/ElectricalMeasurement/Attributes/ActivePower/Desired {"value":0}
2025-07-24T10:53:17+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/ElectricalMeasurement/Attributes/ActivePower/Reported {"value":0}
2025-07-24T10:53:17+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/ElectricalMeasurement/Attributes/RMSVoltage/Desired {"value":239}
2025-07-24T10:53:17+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/ElectricalMeasurement/Attributes/RMSVoltage/Reported {"value":239}
2025-07-24T10:53:17+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/ElectricalMeasurement/Attributes/RMSCurrent/Desired {"value":0}
2025-07-24T10:53:17+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/ElectricalMeasurement/Attributes/RMSCurrent/Reported {"value":0}

Image

When we turn on the loads zpc is not reporting on EP1 and EP2. Only on EP0 it is updating.

2025-07-24T11:00:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/OnOff/Commands/On {}
2025-07-24T11:00:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/Scenes/Attributes/SceneValid/Desired {"value":false}
2025-07-24T11:00:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/OnOff/Attributes/OnOff/Desired {"value":true}
2025-07-24T11:00:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/OnOff/Attributes/OnOff/Desired {"value":true}
2025-07-24T11:00:16+0100 ucl/by-unid/zw-C557CEFA-0002/ep1/OnOff/Attributes/OnOff/Reported {"value":true}
2025-07-24T11:00:19+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/ActivePower/Desired {"value":1769}
2025-07-24T11:00:19+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/ActivePower/Reported {"value":1769}
2025-07-24T11:00:47+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/OnOff/Commands/On {}
2025-07-24T11:00:47+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/Scenes/Attributes/SceneValid/Desired {"value":false}
2025-07-24T11:00:47+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/OnOff/Attributes/OnOff/Desired {"value":true}
2025-07-24T11:00:47+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/OnOff/Attributes/OnOff/Desired {"value":true}
2025-07-24T11:00:47+0100 ucl/by-unid/zw-C557CEFA-0002/ep2/OnOff/Attributes/OnOff/Reported {"value":true}
2025-07-24T11:00:51+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/ActivePower/Desired {"value":2405}
2025-07-24T11:00:51+0100 ucl/by-unid/zw-C557CEFA-0002/ep0/ElectricalMeasurement/Attributes/ActivePower/Reported {"value":2405}

Any solution to this?