Skip to content

Commit 35aafc0

Browse files
authored
add additional line types from pandapower (PyPSA#1342)
1 parent 0fd0a1c commit 35aafc0

4 files changed

Lines changed: 32 additions & 7 deletions

File tree

doc/references/release-notes.rst

Lines changed: 3 additions & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -34,7 +34,9 @@ Features
3434
* The option to set bus-level capacity expansion limits per carrier via `Bus`
3535
attributes `nom_{min/max}_{carrier}_{period}` is now deprecated. The global
3636
constraint type `"tech_capacity_expansion_limit"` offers identical functionality.
37-
37+
38+
* Add additional standard line types from pandapower.
39+
3840
Bug Fixes
3941
---------
4042

pypsa/components/_types/line_types.py

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -31,7 +31,7 @@ class LineTypes(Components):
3131
'LineType' Components
3232
---------------------
3333
Attached to PyPSA Network 'AC-DC-Meshed'
34-
Components: 36
34+
Components: 59
3535
3636
"""
3737

pypsa/components/store.py

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -71,7 +71,7 @@ def __repr__(self) -> str:
7171
- 0 'Store' Components
7272
- 0 'StorageUnit' Components
7373
- 7 'Line' Components
74-
- 36 'LineType' Components
74+
- 59 'LineType' Components
7575
- 0 'Transformer' Components
7676
- 14 'TransformerType' Components
7777
- 0 'ShuntImpedance' Components
@@ -109,7 +109,7 @@ def __getitem__(self, item: str | list | set) -> Any:
109109
- 0 'Store' Components
110110
- 0 'StorageUnit' Components
111111
- 7 'Line' Components
112-
- 36 'LineType' Components
112+
- 59 'LineType' Components
113113
- 0 'Transformer' Components
114114
- 14 'TransformerType' Components
115115
- 0 'ShuntImpedance' Components

pypsa/data/standard_types/line_types.csv

Lines changed: 26 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -9,22 +9,45 @@ name,f_nom,r_per_length,x_per_length,c_per_length,i_nom,mounting,cross_section,r
99
243-AL1/39-ST1A 110.0,50.,0.1188,0.39,9,0.645,ol,243,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013)
1010
243-AL1/39-ST1A 20.0,50.,0.1188,0.32,11,0.645,ol,243,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013)
1111
305-AL1/39-ST1A 110.0,50.,0.0949,0.38,9.2,0.74,ol,305,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013)
12+
34-AL1/6-ST1A 10.0,50.,0.8342,0.36,9.7,0.17,ol,34,pandapower
13+
34-AL1/6-ST1A 20.0,50.,0.8342,0.382,9.15,0.17,ol,34,pandapower
1214
48-AL1/8-ST1A 0.4,50.,0.5939,0.3,12.2,0.21,ol,48,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013)
1315
48-AL1/8-ST1A 10.0,50.,0.5939,0.35,10.1,0.21,ol,48,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013)
1416
48-AL1/8-ST1A 20.0,50.,0.5939,0.372,9.5,0.21,ol,48,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013)
15-
490-AL1/64-ST1A 220.0,50.,0.059,0.285,10,0.96,ol,490,pandapower
16-
490-AL1/64-ST1A 380.0,50.,0.059,0.253,11,0.96,ol,490,pandapower
17+
48-AL1/8-ST1A 110.0,50.,0.5939,0.46,8.0,0.21,ol,48,pandapower
18+
70-AL1/11-ST1A 10.0,50.,0.4132,0.339,10.4,0.29,ol,70,pandapower
19+
70-AL1/11-ST1A 20.0,50.,0.4132,0.36,9.7,0.29,ol,70,pandapower
20+
70-AL1/11-ST1A 110.0,50.,0.4132,0.45,8.4,0.29,ol,70,pandapower
1721
94-AL1/15-ST1A 0.4,50.,0.306,0.29,13.2,0.35,ol,94,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013)
1822
94-AL1/15-ST1A 10.0,50.,0.306,0.33,10.75,0.35,ol,94,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013)
1923
94-AL1/15-ST1A 20.0,50.,0.306,0.35,10,0.35,ol,94,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013)
24+
94-AL1/15-ST1A 110.0,50.,0.306,0.44,8.65,0.35,ol,94,pandapower
25+
122-AL1/20-ST1A 10.0,50.,0.2376,0.323,11.1,0.41,ol,122,pandapower
26+
122-AL1/20-ST1A 20.0,50.,0.2376,0.344,10.3,0.41,ol,122,pandapower
27+
122-AL1/20-ST1A 110.0,50.,0.2376,0.43,8.5,0.41,ol,122,pandapower
28+
490-AL1/64-ST1A 220.0,50.,0.059,0.285,10,0.96,ol,490,pandapower
29+
490-AL1/64-ST1A 380.0,50.,0.059,0.253,11,0.96,ol,490,pandapower
30+
490-AL1/64-ST1A 110.0,50.,0.059,0.37,9.75,0.96,ol,490,pandapower
31+
679-AL1/86-ST1A 110.0,50.,0.042,0.36,9.95,1.15,ol,679,pandapower
32+
679-AL1/86-ST1A 220.0,50.,0.042,0.275,11.7,1.15,ol,679,pandapower
33+
679-AL1/86-ST1A 380.0,50.,0.042,0.25,14.6,1.15,ol,679,pandapower
2034
N2XS(FL)2Y 1x120 RM/35 64/110 kV,50.,0.153,0.166,112,0.366,cs,120,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013);Werth Netzberechnung mit Erzeugungsprofilen
2135
N2XS(FL)2Y 1x185 RM/35 64/110 kV,50.,0.099,0.156,125,0.457,cs,185,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013);Werth Netzberechnung mit Erzeugungsprofilen
2236
N2XS(FL)2Y 1x240 RM/35 64/110 kV,50.,0.075,0.149,135,0.526,cs,240,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013);Werth Netzberechnung mit Erzeugungsprofilen
2337
N2XS(FL)2Y 1x300 RM/35 64/110 kV,50.,0.06,0.144,144,0.588,cs,300,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013);Werth Netzberechnung mit Erzeugungsprofilen
38+
NA2XS2Y 1x95 RM/25 6/10 kV,50.,0.313,0.123,315,0.249,cs,95,pandapower
39+
NA2XS2Y 1x185 RM/25 6/10 kV,50.,0.161,0.11,406,0.358,cs,185,pandapower
40+
NA2XS2Y 1x240 RM/25 6/10 kV,50.,0.122,0.105,456,0.416,cs,240,pandapower
41+
NA2XS2Y 1x150 RM/25 12/20 kV,50.,0.206,0.116,250,0.319,cs,150,pandapower
2442
NA2XS2Y 1x185 RM/25 12/20 kV,50.,0.161,0.117,273,0.362,cs,185,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013);Werth Netzberechnung mit Erzeugungsprofilen
2543
NA2XS2Y 1x240 RM/25 12/20 kV,50.,0.122,0.112,304,0.421,cs,240,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013);Werth Netzberechnung mit Erzeugungsprofilen
44+
NA2XS2Y 1x120 RM/25 12/20 kV,50.,0.253,0.119,230,0.283,cs,120,pandapower
45+
NA2XS2Y 1x70 RM/25 12/20 kV,50.,0.443,0.132,190,0.22,cs,70,pandapower
2646
NA2XS2Y 1x95 RM/25 12/20 kV,50.,0.313,0.132,216,0.252,cs,95,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013);Werth Netzberechnung mit Erzeugungsprofilen
27-
NAYY 4x120 SE,50.,0.225,0.08,264,0.242,cs,120,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013);Werth Netzberechnung mit Erzeugungsprofilen
47+
NA2XS2Y 1x150 RM/25 6/10 kV,50.,0.206,0.11,360,0.315,cs,150,pandapower
48+
NA2XS2Y 1x120 RM/25 6/10 kV,50.,0.253,0.113,340,0.28,cs,120,pandapower
49+
NA2XS2Y 1x70 RM/25 6/10 kV,50.,0.443,0.123,280,0.217,cs,70,pandapower
50+
NAYY 4x120 SE,50.,0.225,0.08,264,0.242,cs,120,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner
2851
NAYY 4x150 SE,50.,0.208,0.08,261,0.27,cs,150,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013);Werth Netzberechnung mit Erzeugungsprofilen
2952
NAYY 4x50 SE,50.,0.642,0.083,210,0.142,cs,50,pandapower;Heuck et al. Elektrische Energieversorgung 8. Auflage (2010); Vierweg+Teubner (2013);Werth Netzberechnung mit Erzeugungsprofilen
3053
Al/St 240/40 2-bundle 220.0,50.,0.06,0.301,12.5,1.29,ol,240,"Oeding and Oswald ""Elektrische Kraftwerke und Netze"", 2011, Chapter 9"

0 commit comments

Comments
 (0)