Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathmotion_controller.rs
More file actions
93 lines (82 loc) · 3.72 KB
/
Copy pathmotion_controller.rs
File metadata and controls
93 lines (82 loc) · 3.72 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
use control_systems_torbox::{
BodePlot, BodePlotOptions, Continuous, FrequencyResponse, NyquistPlot,
NyquistPlotOptions, Plot, Ss, Tf, analysis::frequency_response::lin_space,
};
fn main() {
// This example shows how we can create a plant, design a controller for the
// plant and analyse the resulting closed loop system.
// Plant is integrator, 1/s, and a power converter with a bandwith of 10
// rad/s, and a time delay of 0.5s approximated with a second order pade
// approximation
let s = Tf::s();
let plant = 1.0 / &s * 50.0 / (&s + 50.0) * Tf::pade(0.12, 3);
// let plant = plant.to_ss().unwrap();
// We will use a PI controller: Kp*(1 + 1/T_i*1/s)
// We set the integration time to 1 second and find the largest Kp such that
// Ms = ||S(s)||_inf = peak of sensitity function is less than two.
let ms_limit = 2.0;
let t_i = 10.0;
let kps = lin_space(100.0, 0.001, 100); // Kp to test
let mut controller = None;
for kp in kps {
let controller_i = kp * (1.0 + 1.0 / t_i * 1.0 / &s); //.to_ss().unwrap();
let open_loop = controller_i.series(&plant);
// S = 1/(1 + L)
let sensitivity_func =
Ss::new_from_scalar(1.0).feedback(&open_loop.to_ss().unwrap());
if !sensitivity_func.is_stable() {
continue;
}
let max_sensitivity = sensitivity_func.norm_hinf().unwrap();
// println!("Ms = {}", max_sensitivity);
// println!("Stable: {}", sensitivity_func.is_stable());
let mut bode_plot = BodePlot::new(BodePlotOptions::default());
bode_plot.add_system(sensitivity_func.bode(0.1, 100.).into());
bode_plot.add_system(
Tf::<f64, Continuous>::new_from_scalar(ms_limit)
.bode(0.1, 100.)
.into(),
);
// uncomment if you want to see the progression of the search
// bode_plot.show(600, 400, "Candidate Sensitivity Function").unwrap();
if max_sensitivity < ms_limit {
println!("Found Kp = {}, which gives Ms = {}", kp, max_sensitivity);
controller = Some(controller_i);
break;
}
}
let controller = controller.unwrap();
// Lets look at the properties of the controller and closed loop system
println!("Open Loop transfer function");
let open_loop = controller.series(&plant);
let mut bode_plot = BodePlot::new(BodePlotOptions::default());
bode_plot.add_system(open_loop.bode(0.1, 100.0).into());
bode_plot.show(600, 400, "Open Loop").unwrap();
println!("Sensitivity Function bode plot");
let sensitivity_func = Tf::new_from_scalar(1.0).feedback(&open_loop);
bode_plot = BodePlot::new(BodePlotOptions::default());
bode_plot.add_system(sensitivity_func.bode(0.1, 100.).into());
bode_plot.add_system(
Tf::<f64, Continuous>::new_from_scalar(ms_limit)
.bode(0.1, 100.)
.into(),
);
bode_plot.show(600, 400, "Sensitivity Function").unwrap();
println!("Nyquist plot of open loop");
let mut nyq_plot = NyquistPlot::new(NyquistPlotOptions::default());
nyq_plot.add_system(open_loop.nyquist(0.1, 100.).into());
nyq_plot.show(400, 400, "Nyquist Open Loop").unwrap();
println!("Tracking Function bode plot");
let tracking_func = open_loop.feedback(&Tf::new_from_scalar(1.0));
let mut bode_plot = BodePlot::new(BodePlotOptions::default());
bode_plot.add_system(tracking_func.bode(0.1, 100.).into());
bode_plot
.show(600, 400, "Tracking Function Bode Plot")
.unwrap();
println!("Location of poles: [re, im]");
let poles = tracking_func.to_ss().unwrap().poles();
for pole in poles {
print!("[{:.2}, {:.2}] ", pole.re, pole.im);
}
println!();
}