Skip to content

Commit 82f2bf4

Browse files
committed
update-ML
1 parent 13d9a88 commit 82f2bf4

16 files changed

Lines changed: 51 additions & 109 deletions

input/fsh/ModeleLogiqueMetierCorps/composantsElementaires/FRLMAllergyIntolerance.fsh

Lines changed: 6 additions & 7 deletions
Original file line numberDiff line numberDiff line change
@@ -2,24 +2,23 @@ Logical: FRLMAllergyIntolerance
22
Id: fr-lm-allergy-intolerance
33
Parent: FRLMEntry
44
Title: "Logical model - FR LM Allergy Intolerance"
5-
Description: """Allergie ou hypersensibilite"""
5+
Description: """Modèle logique métier - FR LM Allergie ou Hypersensibilité"""
66
Characteristics: #can-be-target
77

8-
* type 1..1 CodeableConcept "Allergie / hypersensibilité non allergique / intolérance / idiosyncrasie : jdv-type-event-indesirable-previsible-cisis (1.2.250.1.213.1.1.5.842)"
8+
* type 1..1 CodeableConcept "Allergie / hypersensibilité non allergique / intolérance / idiosyncrasie"
99
* ^binding.description = " jdv-type-event-indesirable-previsible-cisis (1.2.250.1.213.1.1.5.842)"
1010
* ^binding.valueSet = "https://smt.esante.gouv.fr/fhir/ValueSet/jdv-type-evenement-indesirable-previsible-cisis"
11-
* category 1..1 CodeableConcept "food | medication | environment | biologic : jdv-hl7-allergy-intolerance-category-cisis (2.16.840.1.113883.4.642.3.133"
12-
/* * ^binding.description = ""
13-
* ^binding.valueSet = "" */
11+
* category 1..1 CodeableConcept "food | medication | environment | biologic"
12+
* ^binding.description = " jdv-hl7-allergy-intolerance-category-cisis (2.16.840.1.113883.4.642.3.133)"
13+
* ^binding.valueSet = ""
1414
* agentOrAllergen 1..1 CodeableConcept "Agent responsable
1515
- Médicaments : CIP ou UCD
1616
- Substances : SMS
1717
- Aliments : CIM-11 Chapitre X Extensions – Allergènes ou substances non médicinales
1818
- Agents environnementaux ou physiques : idem CIM-11 Chapitre X Extensions
1919
- Allergènes pouvant induire une contre-indication vaccinale : jdv-allergie-vaccin-cisis"
2020
* note 0..1 string "commentaire"
21-
* status 0..1 CodeableConcept "Statut clinique de l'allergie
22-
Description du binding: : jdv-hl7-allergyintolerance-clinical-cisis (2.16.840.1.113883.4.642.3.1372)"
21+
* status 0..1 CodeableConcept "Statut clinique de l'allergie"
2322
* ^binding.description = "jdv-hl7-allergyintolerance-clinical-cisis (2.16.840.1.113883.4.642.3.1372)"
2423
* ^binding.valueSet = "https://smt.esante.gouv.fr/fhir/ValueSet/jdv-hl7-allergyintolerance-clinical-cisis"
2524
* criticality 0..1 CodeableConcept "Criticité"
Lines changed: 17 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,17 @@
1+
Logical: FRLMAssessment
2+
Id: fm-lm-assessment
3+
Title: "Logical model - FR LM Assessment"
4+
Description: """Evaluation"""
5+
Characteristics: #can-be-target
6+
7+
* status 1..1 code "Statut de l'évaluation"
8+
* observationDate[x] 1..1 dateTime or Period "date de l'évaluation"
9+
* type 1..1 CodeableConcept "Type d'observation.
10+
- LOINC (2.16.840.1.113883.6.1) ou ICF (2.16.840.1.113883.6.254) ou autre
11+
- Si le type d'évaluation n'est pas trouvé dans les terminologies proposées, utiliser le code='54522-8' displayName='Statut fonctionnel' codeSystem='2.16.840.1.113883.6.1' codeSystemName='LOINC'"
12+
* method 0..1 CodeableConcept "Méthode utilisée pour l'observation"
13+
* bodySite 0..1 CodeableConcept "Site de l'observation"
14+
* result 1..1 CodeableConcept "Valeur de l’évaluation"
15+
* interpretation 0..* CodeableConcept "Interprétation"
16+
* note 0..1 string "Commentaire"
17+
* component 0..* FRLMAssessment "Composant de l'évaluation"

input/fsh/ModeleLogiqueMetierCorps/composantsElementaires/FRLMCertitude.fsh

Lines changed: 0 additions & 12 deletions
This file was deleted.

input/fsh/ModeleLogiqueMetierCorps/composantsElementaires/FRLMCriticite.fsh

Lines changed: 0 additions & 12 deletions
This file was deleted.

input/fsh/ModeleLogiqueMetierCorps/composantsElementaires/FRLMDeviceUse.fsh

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -2,7 +2,7 @@ Logical: FRLMDeviceUse
22
Id: fr-lm-device-use
33
Parent: FRLMEntry
44
Title: "Logical model - FR LM Device use"
5-
Description: """Dispositif médical usage"""
5+
Description: """Modèle logique métier - FR LM Dispositif médical usage"""
66
Characteristics: #can-be-target
77

88
* status 1..1 CodeableConcept "Status de l'utilisation du DM (ex active, completed, etc)."

input/fsh/ModeleLogiqueMetierCorps/composantsElementaires/FRLMEntry.fsh

Lines changed: 1 addition & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -17,5 +17,4 @@ Description: "Modèle logique représentant l'entrée"
1717
* source 0..1 CodeableConcept "Source"
1818
* langue 0..1 CodeableConcept "'fr-FR' pour français métropolitain (la casse des caractères doit être respectée)
1919
La partie en minuscules indique le code de la langue utilisée (ISO-639-1)
20-
La partie en majuscules indique le code pays (ISO-3166)"
21-
* code 0..1 CodeableConcept "Type de l'entrée"
20+
La partie en majuscules indique le code pays (ISO-3166)"

input/fsh/ModeleLogiqueMetierCorps/composantsElementaires/FRLMEvaluation.fsh

Lines changed: 0 additions & 20 deletions
This file was deleted.

input/fsh/ModeleLogiqueMetierCorps/composantsElementaires/FRLMEvaluationComposant.fsh

Lines changed: 0 additions & 15 deletions
This file was deleted.

input/fsh/ModeleLogiqueMetierCorps/composantsElementaires/FRLMEvaluationComposantN2.fsh

Lines changed: 0 additions & 15 deletions
This file was deleted.

input/fsh/ModeleLogiqueMetierCorps/composantsElementaires/FRLMGroupDeQuestionnairesDevaluation.fsh

Lines changed: 1 addition & 1 deletion
Original file line numberDiff line numberDiff line change
@@ -8,4 +8,4 @@ Characteristics: #can-be-target
88
* code 1..1 CodeableConcept "Code de l'entrée"
99
* statut 1..1 code "Statut de l'entrée"
1010
* horodatage 1..1 dateTime "Horodatage de l'entrée"
11-
* evaluation 1..* FRLMEvaluation "Évaluation"
11+
* evaluation 1..* FRLMAssessment "Évaluation"

0 commit comments

Comments
 (0)