Skip to content

Commit f146ca0

Browse files
committed
Resolved the merge conflicts post changing the base branch to v4.1.0-dev
2 parents f0bc106 + 07ea2db commit f146ca0

38 files changed

Lines changed: 1776 additions & 41 deletions

.github/workflows/pytest.yml

Lines changed: 2 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -2,9 +2,9 @@ name: Pytest
22

33
on:
44
push:
5-
branches: [master]
5+
branches: [master, 'v[0-9].[0-9]+.[0-9]+*']
66
pull_request:
7-
branches: [master]
7+
branches: [master, 'v[0-9].[0-9]+.[0-9]+*']
88

99
permissions:
1010
contents: read

.gitignore

Lines changed: 1 addition & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -50,6 +50,7 @@ coverage.xml
5050
.hypothesis/
5151
.pytest_cache/
5252
cover/
53+
preupgrade_validator*.tgz
5354

5455
# Translations
5556
*.mo

aci-preupgrade-validation-script.py

Lines changed: 260 additions & 12 deletions
Large diffs are not rendered by default.

docs/docs/validations.md

Lines changed: 96 additions & 8 deletions
Original file line numberDiff line numberDiff line change
@@ -82,7 +82,7 @@ Items | Faults | This Script
8282
[Fabric Port Status][f19] | F1394: ethpm-if-port-down-fabric | :white_check_mark: | :no_entry_sign:
8383
[Equipment Disk Limits][f20] | F1820: 80% -minor<br>F1821: -major<br>F1822: -critical | :white_check_mark: | :no_entry_sign:
8484
[VMM Inventory Partially Synced][f21] | F0132: comp-ctrlr-operational-issues | :white_check_mark: | :no_entry_sign:
85-
85+
[APIC Storage Inode Usage][f22] | F4388: 75% - 85% -warning<br>F4389: 85% - 90% -major<br>F4390: 90% or more -critical | :white_check_mark: | :no_entry_sign:
8686

8787
[f1]: #apic-disk-space-usage
8888
[f2]: #standby-apic-disk-space-usage
@@ -105,6 +105,7 @@ Items | Faults | This Script
105105
[f19]: #fabric-port-status
106106
[f20]: #equipment-disk-limits
107107
[f21]: #vmm-inventory-partially-synced
108+
[f22]: #apic-storage-inode-usage
108109

109110
### Configuration Checks
110111

@@ -194,7 +195,10 @@ Items | Defect | This Script
194195
[ISIS DTEPs Byte Size][d27] | CSCwp15375 | :white_check_mark: | :no_entry_sign:
195196
[Policydist configpushShardCont Crash][d28] | CSCwp95515 | :white_check_mark: | :no_entry_sign:
196197
[Auto Firmware Update on Switch Discovery][d29] | CSCwe83941 | :white_check_mark: | :no_entry_sign:
197-
[Inband Management Policy Misconfiguration][d30]| CSCwd40071 | :white_check_mark: | :no_entry_sign:
198+
[Rogue EP Exception List missing on switches][d30] | CSCwp64296 | :white_check_mark: | :no_entry_sign:
199+
[N9K-C9408 with more than 5 N9K-X9400-16W LEMs][d31] | CSCws82819 | :white_check_mark: | :no_entry_sign:
200+
[Multi-Pod Modular Spine Bootscript File][d32] | CSCwr66848 | :white_check_mark: | :no_entry_sign:
201+
[Inband Management Policy Misconfiguration][d33]| CSCwd40071 | :white_check_mark: | :no_entry_sign:
198202

199203
[d1]: #ep-announce-compatibility
200204
[d2]: #eventmgr-db-size-defect-susceptibility
@@ -225,7 +229,10 @@ Items | Defect | This Script
225229
[d27]: #isis-dteps-byte-size
226230
[d28]: #policydist-configpushshardcont-crash
227231
[d29]: #auto-firmware-update-on-switch-discovery
228-
[d30]: #inband-management-policy-misconfiguration
232+
[d30]: #rogue-ep-exception-list-missing-on-switches
233+
[d31]: #n9k-c9408-with-more-than-5-n9k-x9400-16w-lems
234+
[d32]: #multi-pod-modular-spine-bootscript-file
235+
[d33]: #inband-management-policy-misconfiguration
229236

230237
## General Check Details
231238

@@ -1553,6 +1560,56 @@ EPGs using the `pre-provision` resolution immediacy do not rely on the VMM inven
15531560

15541561
This check returns a `MANUAL` result as there are many reasons for a partial inventory sync to be reported. The goal is to ensure that the VMM inventory sync has fully completed before triggering the APIC upgrade to reduce any chance for unexpected inventory changes to occur.
15551562

1563+
1564+
### APIC Storage Inode Usage
1565+
1566+
If a Cisco APIC is running low on inode capacity for any reason, the Cisco APIC upgrade can fail. The Cisco APIC will raise three different faults depending on inode utilization. If any of these faults are raised on the system, the issue should be resolved prior to performing the upgrade.
1567+
1568+
* **F4388**: A warning level fault for Cisco APIC storage inode utilization. This is raised when utilization is greater than 75%.
1569+
1570+
* **F4389**: A major level fault for Cisco APIC storage inode utilization. This is raised when utilization is between 85% and 90%.
1571+
1572+
* **F4390**: A critical level fault for Cisco APIC storage inode utilization. This is raised when utilization is greater than 90%.
1573+
1574+
Although the storage space for the filesystem might be adequate we might still see issues with inode usage, this happens when we have more number of files or directories created with lower file sizes.
1575+
1576+
Recommended Action:
1577+
1578+
To recover from this fault, try the following action
1579+
1580+
1. Free up space from affected disk partition .
1581+
2. TAC may be required to analyze and cleanup certain directories due to filesystem permissions. Cleanup of `/` is one such example.
1582+
1583+
!!! example "Fault Example (F4390: Critical fault for APIC Inode Utilisation)"
1584+
```
1585+
moquery -c faultInst -f 'fault.Inst.code=="F4390"'
1586+
Total Objects shown: 1
1587+
1588+
# faultInst
1589+
ack : yes
1590+
alert : no
1591+
cause : equipment-full
1592+
changeSet : available (Old: 19408344, New: 19407972), inodesFree (Old: 263915, New: 263842), inodesUsed (Old: 2357525, New: 2357598),
1593+
used (Old: 19436092, New: 19436464)
1594+
code : F4390
1595+
created : 2024-08-05T05:42:31.975+02:00
1596+
delegated : no
1597+
descr : Storage unit /scratch-writes on node 3 with hostname apic3 mounted at /scratch-writes is 90% full for Inodes
1598+
dn : topology/pod-2/node-3/sys/ch/p-[/scratch-writes]-f-[/dev/mapper/atx-scratch]/fault-F4390
1599+
domain : infra
1600+
highestSeverity : critical
1601+
lastTransition : 2024-08-05T09:41:18.152+02:00
1602+
lc : raised
1603+
occur : 2
1604+
origSeverity : critical
1605+
prevSeverity : cleared
1606+
rule : eqpt-storage-inode-critical
1607+
severity : critical
1608+
subject : equipment-full
1609+
type : operational
1610+
```
1611+
1612+
15561613
## Configuration Check Details
15571614

15581615
### VPC-paired Leaf switches
@@ -2650,6 +2707,7 @@ Due to [CSCwp95515][59], upgrading to an affected version while having any `conf
26502707

26512708
If any instances of `configpushShardCont` are flagged by this script, Cisco TAC must be contacted to identify and resolve the underlying issue before performing the upgrade.
26522709

2710+
26532711
### Auto Firmware Update on Switch Discovery
26542712

26552713
[Auto Firmware Update on Switch Discovery][63] automatically upgrades a new switch to the target firmware version before registering it to the ACI fabric. This feature activates in three scenarios:
@@ -2670,15 +2728,42 @@ To avoid this risk, consider disabling Auto Firmware Update before upgrading to
26702728
This issue occurs because older switch firmware versions are not compatible with switch images 6.0(3) or newer. The APIC version is not a factor.
26712729

26722730

2731+
### Rogue EP Exception List missing on switches
2732+
2733+
The Rogue/COOP Exception List feature, introduced in 5.2(3), allows exclusion of specific MAC addresses from Rogue Endpoint Control and COOP Dampening. Initially, each MAC address had to be configured individually in each bridge domain. In 6.0(3), this feature was enhanced to support fabric-wide exception lists with wildcard options per bridge domain and the ability to exclude MAC addresses in L3Outs.
2734+
2735+
However, due to [CSCwp64296][64], when upgrading spine switches to version 6.0(3)+ from an older version with Rogue/COOP Exception Lists configured, some exception lists may not be pushed to the spine switches. As a result, the feature may stop functioning after the upgrade.
2736+
2737+
The root cause is that internal objects called `presListener` for Rogue/COOP Exception List, which publish the configuration from APICs to switches, may be missing on the APICs after an upgrade.
2738+
2739+
Recommended action: Delete the affected exception list and create it again. If needed, contact Cisco TAC to help recover missing `presListener` objects on APICs.
2740+
2741+
2742+
### N9K-C9408 with more than 5 N9K-X9400-16W LEMs
2743+
2744+
Due to defect [CSCws82819][65], N9K-C9408 switch will experience a boot loop with dt_helper process crash if upgraded to versions 16.1(2f) to 16.1(5) or 16.2(1g) with more than 5 N9K-X9400-16W LEMs installed.
2745+
2746+
To avoid this issue, please upgrade to fix version or use less than 6 N9K-X9400-16W in one chassis.
2747+
2748+
2749+
### Multi-Pod Modular Spine Bootscript File
2750+
2751+
Due to [CSCwr66848][66], in Multi-Pod environments, upgrading a modular spine to 6.1(4h) may result in inter-pod traffic to stop working if the `/bootflash/bootscript` file is missing on the spine prior to the upgrade. The traffic interruption occurs because the spine incorrectly indentifies the reason of its reload, leading to an unnecessary attempt to load the missing bootscript file.
2752+
2753+
This issue happens only when the target version is specifically 6.1(4h).
2754+
2755+
To avoid this issue, change the target version to another version. Or verify that the `bootscript` file exists in the bootflash of each modular spine switch prior to upgrading to 6.1(4h). If the file is missing, you have to do clean reboot on the impacted spine to ensure that `/bootflash/bootscript` gets created again. In case you already upgraded your spine and you are experiencing the traffic impact due to this issue, clean reboot of the spine will restore the traffic.
2756+
2757+
26732758
### Inband Management Policy Misconfiguration
26742759

26752760
RCA:
26762761

2677-
Due to the defect [CSCwh80837][64], starting from version 6.0(4c), an implicit deletion of `fvRsCustQosPol` was introduced under InBand EPG as QoS configuration is not applicable to management inband EPG and it was raising an invalid fault under it. This implicit deletion triggers a re-processing and pushes updates to `fvInBEpP` (Inband Endpoint Profile) on leaf nodes where the inband management policy is deployed.
2762+
Due to the defect [CSCwh80837][67], starting from version 6.0(4c), an implicit deletion of `fvRsCustQosPol` was introduced under InBand EPG as QoS configuration is not applicable to management inband EPG and it was raising an invalid fault under it. This implicit deletion triggers a re-processing and pushes updates to `fvInBEpP` (Inband Endpoint Profile) on leaf nodes where the inband management policy is deployed.
26782763

26792764
Impact:
26802765

2681-
When upgrading from versions prior to 6.0(4c) to versions 6.0(4c) or later, if there is a misconfiguration in the inband management policies (`mgmtRsInBStNode`) with invalid values, the re-processing triggered by [CSCwh80837][64] will expose the underlying [CSCwd40071][65] defect. This results in continuous policyelem core dumps and switch reboot when attempting to add any access policies configuration to a leaf switch (such as VLANs tied to leaf profiles via physical domain, AAEP, interface policy group, or port selector).
2766+
When upgrading from versions prior to 6.0(4c) to versions 6.0(4c) or later, if there is a misconfiguration in the inband management policies (`mgmtRsInBStNode`) with invalid values, the re-processing triggered by [CSCwh80837][67] will expose the underlying [CSCwd40071][68] defect. This results in continuous policyelem core dumps and switch reboot when attempting to add any access policies configuration to a leaf switch (such as VLANs tied to leaf profiles via physical domain, AAEP, interface policy group, or port selector).
26822767

26832768
The invalid configuration occurs when `mgmtRsInBStNode` has "0.0.0.0" values (with no mask) for either the "addr" or "gw" fields.
26842769

@@ -2687,7 +2772,7 @@ Suggestion:
26872772
This check identifies misconfigured `mgmtRsInBStNode` objects where either "addr" or "gw" attributes are set to "0.0.0.0" when the upgrade crosses the 6.0(4c) release boundary. Contact Cisco TAC to remove any identified misconfigured objects before performing the upgrade to prevent policyelem crashes.
26882773

26892774
!!! note
2690-
The [CSCwd40071][65] defect affects versions 5.2(5c) and later, with a fix available in 6.0(1g). However, the issue will only be triggered during upgrades crossing 6.0(4c) due to [CSCwh80837][64].
2775+
The [CSCwd40071][68] defect affects versions 5.2(5c) and later, with a fix available in 6.0(1g). However, the issue will only be triggered during upgrades crossing 6.0(4c) due to [CSCwh80837][67].
26912776

26922777

26932778
[0]: https://github.com/datacenter/ACI-Pre-Upgrade-Validation-Script
@@ -2754,5 +2839,8 @@ This check identifies misconfigured `mgmtRsInBStNode` objects where either "addr
27542839
[61]: https://www.cisco.com/c/en/us/solutions/collateral/data-center-virtualization/application-centric-infrastructure/white-paper-c11-743951.html#EnablePolicyCompression
27552840
[62]: https://bst.cloudapps.cisco.com/bugsearch/bug/CSCwe83941
27562841
[63]: https://www.cisco.com/c/en/us/td/docs/dcn/aci/apic/all/apic-installation-aci-upgrade-downgrade/Cisco-APIC-Installation-ACI-Upgrade-Downgrade-Guide/m-auto-firmware-update.html
2757-
[64]: https://bst.cloudapps.cisco.com/bugsearch/bug/CSCwh80837
2758-
[65]: https://bst.cloudapps.cisco.com/bugsearch/bug/CSCwd40071
2842+
[64]: https://bst.cloudapps.cisco.com/bugsearch/bug/CSCwp64296
2843+
[65]: https://bst.cloudapps.cisco.com/bugsearch/bug/CSCws82819
2844+
[66]: https://bst.cloudapps.cisco.com/bugsearch/bug/CSCwr66848
2845+
[67]: https://bst.cloudapps.cisco.com/bugsearch/bug/CSCwh80837
2846+
[68]: https://bst.cloudapps.cisco.com/bugsearch/bug/CSCwd40071
Lines changed: 80 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,80 @@
1+
[
2+
{
3+
"faultInst": {
4+
"attributes": {
5+
"ack": "no",
6+
"alert": "no",
7+
"cause": "equipment-full",
8+
"changeSet": "available (Old: 37868344, New: 37859228), inodesFree (Old: 810163, New: 479339), inodesUsed (Old: 1811277, New: 2142101), inodesUtilized (Old: 70, New: 82), used (Old: 976092, New: 985208)",
9+
"code": "F4388",
10+
"created": "2026-03-06T11:58:43.579+00:00",
11+
"delegated": "no",
12+
"descr": "Storage unit /data/admin/bin/avread on Node 1 mounted at /data/admin/bin/avread is 82% full for Inodes",
13+
"dn": "topology/pod-1/node-1/sys/ch/p-[/data/admin/bin/avread]-f-[overlayfs]/fault-F4388",
14+
"domain": "infra",
15+
"highestSeverity": "warning",
16+
"lastTransition": "2026-03-06T11:58:43.579+00:00",
17+
"lc": "raised",
18+
"occur": "1",
19+
"origSeverity": "warning",
20+
"prevSeverity": "warning",
21+
"rule": "eqpt-storage-inode-warning",
22+
"severity": "warning",
23+
"subject": "equipment-full",
24+
"type": "operational"
25+
}
26+
}
27+
},
28+
{
29+
"faultInst": {
30+
"attributes": {
31+
"ack": "no",
32+
"alert": "no",
33+
"cause": "equipment-full",
34+
"changeSet": "available (Old: 37868344, New: 37859228), inodesFree (Old: 810163, New: 479339), inodesUsed (Old: 1811277, New: 2142101), inodesUtilized (Old: 70, New: 82), used (Old: 976092, New: 985208)",
35+
"code": "F4388",
36+
"created": "2026-03-06T11:58:43.587+00:00",
37+
"delegated": "no",
38+
"descr": "Storage unit /etc/hosts on Node 1 mounted at /etc/hosts is 82% full for Inodes",
39+
"dn": "topology/pod-1/node-1/sys/ch/p-[/etc/hosts]-f-[overlayfs]/fault-F4388",
40+
"domain": "infra",
41+
"highestSeverity": "warning",
42+
"lastTransition": "2026-03-06T11:58:43.587+00:00",
43+
"lc": "soaking",
44+
"occur": "1",
45+
"origSeverity": "warning",
46+
"prevSeverity": "warning",
47+
"rule": "eqpt-storage-inode-warning",
48+
"severity": "warning",
49+
"subject": "equipment-full",
50+
"type": "operational"
51+
}
52+
}
53+
},
54+
{
55+
"faultInst": {
56+
"attributes": {
57+
"ack": "no",
58+
"alert": "no",
59+
"cause": "equipment-full",
60+
"changeSet": "available (Old: 37868344, New: 37859228), inodesFree (Old: 810163, New: 479339), inodesUsed (Old: 1811277, New: 2142101), inodesUtilized (Old: 70, New: 82), used (Old: 976092, New: 985208)",
61+
"code": "F4388",
62+
"created": "2026-03-06T11:58:43.595+00:00",
63+
"delegated": "no",
64+
"descr": "Storage unit /scratch-writes on Node 1 mounted at /scratch-writes is 82% full for Inodes",
65+
"dn": "topology/pod-1/node-1/sys/ch/p-[/scratch-writes]-f-[/dev/mapper/atx-scratch]/fault-F4388",
66+
"domain": "infra",
67+
"highestSeverity": "warning",
68+
"lastTransition": "2026-03-06T11:58:43.595+00:00",
69+
"lc": "raised-clearing",
70+
"occur": "1",
71+
"origSeverity": "warning",
72+
"prevSeverity": "warning",
73+
"rule": "eqpt-storage-inode-warning",
74+
"severity": "warning",
75+
"subject": "equipment-full",
76+
"type": "operational"
77+
}
78+
}
79+
}
80+
]
Lines changed: 54 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,54 @@
1+
[
2+
{
3+
"faultInst": {
4+
"attributes": {
5+
"ack": "no",
6+
"alert": "no",
7+
"cause": "equipment-full",
8+
"changeSet": "available (Old: 37868344, New: 37859228), inodesFree (Old: 810163, New: 479339), inodesUsed (Old: 1811277, New: 2142101), inodesUtilized (Old: 70, New: 82), used (Old: 976092, New: 985208)",
9+
"code": "F4388",
10+
"created": "2026-03-06T11:58:43.579+00:00",
11+
"delegated": "no",
12+
"descr": "Storage unit /data/admin/bin/avread on Node 1 mounted at /data/admin/bin/avread is 82% full for Inodes",
13+
"dn": "topology/pod-1/node-1/sys/ch/p-[/data/admin/bin/avread]-f-[overlayfs]/fault-F4388",
14+
"domain": "infra",
15+
"highestSeverity": "warning",
16+
"lastTransition": "2026-03-06T11:58:43.579+00:00",
17+
"lc": "cleared",
18+
"occur": "1",
19+
"origSeverity": "warning",
20+
"prevSeverity": "warning",
21+
"rule": "eqpt-storage-inode-warning",
22+
"severity": "warning",
23+
"subject": "equipment-full",
24+
"type": "operational"
25+
}
26+
}
27+
},
28+
{
29+
"faultInst": {
30+
"attributes": {
31+
"ack": "no",
32+
"alert": "no",
33+
"cause": "equipment-full",
34+
"changeSet": "available (Old: 37868344, New: 37859228), inodesFree (Old: 810163, New: 479339), inodesUsed (Old: 1811277, New: 2142101), inodesUtilized (Old: 70, New: 82), used (Old: 976092, New: 985208)",
35+
"code": "F4388",
36+
"created": "2026-03-06T11:58:43.587+00:00",
37+
"delegated": "no",
38+
"descr": "Storage unit /etc/hosts on Node 1 mounted at /etc/hosts is 82% full for Inodes",
39+
"dn": "topology/pod-1/node-1/sys/ch/p-[/etc/hosts]-f-[overlayfs]/fault-F4388",
40+
"domain": "infra",
41+
"highestSeverity": "warning",
42+
"lastTransition": "2026-03-06T11:58:43.587+00:00",
43+
"lc": "retaining",
44+
"occur": "1",
45+
"origSeverity": "warning",
46+
"prevSeverity": "warning",
47+
"rule": "eqpt-storage-inode-warning",
48+
"severity": "warning",
49+
"subject": "equipment-full",
50+
"type": "operational"
51+
}
52+
}
53+
}
54+
]

0 commit comments

Comments