The following shows PWM module APIs available for each platform.
| Linux (Ubuntu) |
Tizen (ARTIK530) |
Raspbian (Raspberry Pi) |
NuttX (STM32F4-Discovery) |
TizenRT (ARTIK053) |
|
|---|---|---|---|---|---|
| pwm.open | X | O | O | O | O |
| pwm.openSync | X | O | O | O | O |
| pwmpin.setPeriod | X | O | O | O | O |
| pwmpin.setPeriodSync | X | O | O | O | O |
| pwmpin.setFrequency | X | O | O | O | O |
| pwmpin.setFrequencySync | X | O | O | O | O |
| pwmpin.setDutyCycle | X | O | O | O | O |
| pwmpin.setDutyCycleSync | X | O | O | O | O |
| pwmpin.setEnable | X | O | O | O | O |
| pwmpin.setEnableSync | X | O | O | O | O |
| pwmpin.close | X | O | O | O | O |
| pwmpin.closeSync | X | O | O | O | O |
configuration{Object} Configuration object which can have the following properties.pin{number} The pin number to use with this PWM object (mandatory configuration).chip{number} The PWM chip number (only on Linux). Default:0.period{number} The period of the PWM signal, in seconds (positive number).dutyCycle{number} The active time of the PWM signal, must be within the0.0and1.0range.
callback{Function} Callback function.err{Error|null} The error object ornullif there were no error.pwmpin{Object} An instance of PWMPin.
- Returns: {Object} An instance of PWMPin.
Opens PWM pin with the specified configuration.
To correctly open a PWM pin one must know the correct pin number:
- On Linux,
pinis a number which is0or1. - On Tizen,
pinis a number which is2. (Only ARTIK530 board support PWM.) - On NuttX, you have to know pin name. The pin name is defined in target board module. For more module information, please see below list.
Example
var pwm = require('pwm');
var config = {
pin: 0,
period: 0.1,
dutyCycle: 0.5
}
var pwm0 = pwm.open(config, function(err) {
if (err) {
throw err;
}
});configuration{Object} Configuration object which can have the following properties.pin{number} The pin number to use with this PWM object (mandatory configuration).chip{number} The PWM chip number (only on Linux). Default:0.period{number} The period of the PWM signal, in seconds (positive number).dutyCycle{number} The active time of the PWM signal, must be within the0.0and1.0range.
- Returns: {Object} An instance of PWMPin.
Opens PWM pin with the specified configuration.
To correctly open a PWM pin one must know the correct pin number:
- On Linux,
pinis a number which is0or1. - On NuttX, you have to know pin name. The pin name is defined in target board module. For more module information, please see below list.
Example
var pwm = require('pwm');
var config = {
pin: 0,
period: 0.1,
dutyCycle: 0.5
}
var pwm0 = pwm.openSync(config);period{number} The period of the PWM signal, in seconds (positive number).callback{Function}err{Error|null} The error object ornullif there were no error.
The setPeriod method allows the configuration of the period of the PWM signal in seconds.
The period argument must specified and it should be a positive number.
Configuration is done asynchronously and the callback method is invoked after the
period is configured to the new value or if an error occured.
Example
pwm0.setPeriod(1, function(err) {
if (err) {
throw err;
}
console.log('done');
});
// prints: do
console.log('do');
// prints: doneperiod{number} The period of the PWM signal, in seconds (positive number).
The setPeriodSync method allows the configuration of the period of the PWM signal in seconds.
The period argument must specified and it should be a positive number.
Configuration is done synchronously and will block till the period is configured.
Example
pwm0.setPeriodSync(1);
// prints: done
console.log('done');frequency{integer} In Hz (positive integer).callback{Function}err{Error|null} The error object ornullif there were no error.
The setFrequency method configures the frequency of the PWM signal.
frequency is the measurement of how often the signal is repeated in a single period.
Configuration is done asynchronously and the callback method is invoked after the
frequency is configured to the new value or if an error occured.
Example
pwm0.setFrequency(1, function(err) {
if (err) {
throw err;
}
console.log('done');
});
// prints: do
console.log('do');
// prints: donefrequency{integer} In Hz (positive integer).
The setFrequencySync method configures the frequency of the PWM signal.
frequency is the measurement of how often the signal is repeated in a single period.
Configuration is done synchronously and will block till the frequency is configured.
Example
pwm0.setFrequencySync(1);
// prints: done
console.log('done');dutyCycle{number} Must be within the0.0and1.0range.callback{Function}err{Error|null} The error object ornullif there were no error.
The setDutyCycle method allows the configuration of the duty cycle of the PWM signal.
The duty cycle is the ratio of the pulse width in one period.
Configuration is done asynchronously and the callback method is invoked after the
duty cycle is configured to the new value or if an error occured.
Example
pwm0.setDutyCycle(1, function(err) {
if (err) {
throw err;
}
console.log('done');
});
// prints: do
console.log('do');
// prints: donedutyCycle{number} Must be within the0.0and1.0range.
The setDutyCycleSync method allows the configuration of the duty cycle of the PWM signal.
The duty cycle is the ratio of the pulse width in one period.
Configuration is done synchronously and will block till the duty cycle is configured.
Example
pwm0.setDutyCycleSync(1);
// prints: done
console.log('done');enable{boolean}callback{Function}err{Error|null} The error object ornullif there were no error.
The setEnable method can turn on/off the generation of the PWM signal.
If the enable argument is true then the PWN signal generation is turned on.
Otherwise the signal generation is turned off.
After enabling/disabling the signal generation the callback is invoked.
Example
pwm0.setEnable(true, function(err) {
if (err) {
throw err;
}
console.log('done');
});
// prints: do
console.log('do');
// prints: doneenable{boolean}
The setEnableSync method can turn on/off the generation of the PWM signal.
If the enable argument is true then the PWN signal generation is turned on.
Otherwise the signal generation is turned off.
Example
pwm0.setEnableSync(false);
// prints: done
console.log('done');callback{Function}err{Error|null} The error object ornullif there were no error.
The close method closes the PWM pin asynchronously.
The callback method will be invoked after the PWM device is released.
Example
pwm0.close(function(err) {
if (err) {
throw err;
}
console.log('done');
});
// prints: do
console.log('do');
// prints: doneThe closeSync method closes the PWM pin synchronously.
Example
pwm0.closeSync();
// prints: done