SYNOPSIS

Retrieves alerts for a specific LogicMonitor device.

SYNTAX

Id (Default)

Get-LMDeviceAlert -Id <Int32> [-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>]
 [<CommonParameters>]

Name

Get-LMDeviceAlert [-Name <String>] [-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>]
 [<CommonParameters>]

DESCRIPTION

The Get-LMDeviceAlerts function retrieves all alerts associated with a specific device in LogicMonitor. The device can be identified by either ID or name, and the results can be filtered using custom criteria.

EXAMPLES

EXAMPLE 1

#Retrieve alerts for a device by ID
Get-LMDeviceAlerts -Id 123

EXAMPLE 2

#Retrieve alerts for a device by name with filtering
Get-LMDeviceAlerts -Name "Production-Server" -Filter $filterObject

PARAMETERS

-Id

The ID of the device to retrieve alerts for. This parameter is mandatory when using the Id parameter set and can accept pipeline input.

Type: Int32
Parameter Sets: Id
Aliases:

Required: True
Position: Named
Default value: 0
Accept pipeline input: True (ByPropertyName)
Accept wildcard characters: False

-Name

The name of the device to retrieve alerts for. Part of a mutually exclusive parameter set.

Type: String
Parameter Sets: Name
Aliases:

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Filter

A filter object to apply when retrieving alerts. This parameter is optional.

Type: Object
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-BatchSize

The number of results to return per request. Must be between 1 and 1000. Defaults to 1000.

Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: 1000
Accept pipeline input: False
Accept wildcard characters: False

-ProgressAction

{{ Fill ProgressAction Description }}

Type: ActionPreference
Parameter Sets: (All)
Aliases: proga

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

System.Int32. The device ID can be piped to this function.

OUTPUTS

Returns LogicMonitor.Alert objects.

NOTES

You must run Connect-LMAccount before running this command.