| external help file | Logic.Monitor-help.xml |
|---|---|
| Module Name | Logic.Monitor |
| online version | |
| schema | 2.0.0 |
Retrieves configuration source data for a LogicMonitor device.
Get-LMDeviceConfigSourceData -Id <Int32> -HdsId <String> -HdsInsId <String>
[-ProgressAction <ActionPreference>] [<CommonParameters>]
Get-LMDeviceConfigSourceData -Id <Int32> -HdsId <String> -HdsInsId <String> [-ConfigId <String>]
[-ProgressAction <ActionPreference>] [<CommonParameters>]
Get-LMDeviceConfigSourceData -Id <Int32> -HdsId <String> -HdsInsId <String> [-LatestConfigOnly]
[-ConfigType <String>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
The Get-LMDeviceConfigSourceData function retrieves configuration data from a specific device's configuration source in LogicMonitor. It supports retrieving full configurations or delta changes, and can return either all configs or just the latest one.
#Retrieve latest configuration for a device
Get-LMDeviceConfigSourceData -Id 123 -HdsId 456 -HdsInsId 789 -LatestConfigOnly
#Retrieve full configuration history
Get-LMDeviceConfigSourceData -Id 123 -HdsId 456 -HdsInsId 789 -ConfigType Full
The ID of the device to retrieve configuration data for. This parameter is mandatory.
Type: Int32
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: FalseThe ID of the host datasource. This parameter is mandatory.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThe ID of the host datasource instance. This parameter is mandatory.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThe specific configuration ID to retrieve. Part of a mutually exclusive parameter set.
Type: String
Parameter Sets: ConfigId
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseSwitch to retrieve only the most recent configuration. Part of the ListConfigs parameter set.
Type: SwitchParameter
Parameter Sets: ListConfigs
Aliases:
Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: FalseThe type of configuration to retrieve. Valid values are "Delta" or "Full". Defaults to "Delta".
Type: String
Parameter Sets: ListConfigs
Aliases:
Required: False
Position: Named
Default value: Delta
Accept pipeline input: False
Accept wildcard characters: False{{ Fill ProgressAction Description }}
Type: ActionPreference
Parameter Sets: (All)
Aliases: proga
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThis cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
You must run Connect-LMAccount before running this command.