| external help file | Logic.Monitor-help.xml |
|---|---|
| Module Name | Logic.Monitor |
| online version | |
| schema | 2.0.0 |
Retrieves alert recipients for a specific data point in a LogicMonitor device datasource instance.
Get-LMDeviceDatasourceInstanceAlertRecipient -DatasourceName <String> -Name <String> -InstanceName <String>
-DataPointName <String> [-ProgressAction <ActionPreference>] [<CommonParameters>]
Get-LMDeviceDatasourceInstanceAlertRecipient -DatasourceName <String> -Id <Int32> -InstanceName <String>
-DataPointName <String> [-ProgressAction <ActionPreference>] [<CommonParameters>]
Get-LMDeviceDatasourceInstanceAlertRecipient -DatasourceId <Int32> -Name <String> -InstanceName <String>
-DataPointName <String> [-ProgressAction <ActionPreference>] [<CommonParameters>]
Get-LMDeviceDatasourceInstanceAlertRecipient -DatasourceId <Int32> -Id <Int32> -InstanceName <String>
-DataPointName <String> [-ProgressAction <ActionPreference>] [<CommonParameters>]
The Get-LMDeviceDatasourceInstanceAlertRecipient function retrieves the alert recipients configured for a specific data point within a device's datasource instance. It supports identifying the device and datasource by either ID or name.
#Retrieve alert recipients using names
Get-LMDeviceDatasourceInstanceAlertRecipient -DatasourceName "Ping" -Name "Server01" -InstanceName "Instance01" -DataPointName "PingLossPercent"
#Retrieve alert recipients using IDs
Get-LMDeviceDatasourceInstanceAlertRecipient -DatasourceId 123 -Id 456 -InstanceName "Instance01" -DataPointName "PingLossPercent"
The name of the datasource. Required for Id-dsName and Name-dsName parameter sets.
Type: String
Parameter Sets: Name-dsName, Id-dsName
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThe ID of the datasource. Required for Id-dsId and Name-dsId parameter sets.
Type: Int32
Parameter Sets: Name-dsId, Id-dsId
Aliases:
Required: True
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: FalseThe ID of the device. Can be specified using the DeviceId alias. Required for Id-dsId and Id-dsName parameter sets.
Type: Int32
Parameter Sets: Id-dsName, Id-dsId
Aliases: DeviceId
Required: True
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: FalseThe name of the device. Can be specified using the DeviceName alias. Required for Name-dsName and Name-dsId parameter sets.
Type: String
Parameter Sets: Name-dsName, Name-dsId
Aliases: DeviceName
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThe name of the datasource instance. This parameter is mandatory.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThe name of the data point to retrieve alert recipients for. This parameter is mandatory.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False{{ Fill ProgressAction Description }}
Type: ActionPreference
Parameter Sets: (All)
Aliases: proga
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThis cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
You must run Connect-LMAccount before running this command.