| external help file | Logic.Monitor-help.xml |
|---|---|
| Module Name | Logic.Monitor |
| online version | |
| schema | 2.0.0 |
Retrieves alert settings for a LogicMonitor device datasource instance.
Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceName <String> -Name <String> -InstanceName <String>
[-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceName <String> -Id <Int32> -InstanceName <String>
[-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceId <Int32> -Name <String> -InstanceName <String>
[-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
Get-LMDeviceDatasourceInstanceAlertSetting -DatasourceId <Int32> -Id <Int32> -InstanceName <String>
[-Filter <Object>] [-BatchSize <Int32>] [-ProgressAction <ActionPreference>] [<CommonParameters>]
The Get-LMDeviceDatasourceInstanceAlertSetting function retrieves the alert configuration settings for a specific device datasource instance. It supports identifying the device and datasource by either ID or name, and allows filtering of the results.
#Retrieve alert settings using names
Get-LMDeviceDatasourceInstanceAlertSetting -Name "MyDevice" -DatasourceName "MyDatasource" -InstanceName "MyInstance"
#Retrieve alert settings using IDs with filter
Get-LMDeviceDatasourceInstanceAlertSetting -Id 123 -DatasourceId 456 -InstanceName "MyInstance" -Filter $filterObject
The name of the datasource. Required for Id-dsName and Name-dsName parameter sets.
Type: String
Parameter Sets: Name-dsName, Id-dsName
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThe ID of the datasource. Required for Id-dsId and Name-dsId parameter sets.
Type: Int32
Parameter Sets: Name-dsId, Id-dsId
Aliases:
Required: True
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: FalseThe ID of the device. Can be specified using the DeviceId alias. Required for Id-dsId and Id-dsName parameter sets.
Type: Int32
Parameter Sets: Id-dsName, Id-dsId
Aliases: DeviceId
Required: True
Position: Named
Default value: 0
Accept pipeline input: False
Accept wildcard characters: FalseThe name of the device. Can be specified using the DeviceName alias. Required for Name-dsName and Name-dsId parameter sets.
Type: String
Parameter Sets: Name-dsName, Name-dsId
Aliases: DeviceName
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThe name of the instance to retrieve alert settings for. This parameter is mandatory.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseA filter object to apply when retrieving alert settings. This parameter is optional.
Type: Object
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThe number of results to return per request. Must be between 1 and 1000. Defaults to 1000.
Type: Int32
Parameter Sets: (All)
Aliases:
Required: False
Position: Named
Default value: 1000
Accept pipeline input: False
Accept wildcard characters: False{{ Fill ProgressAction Description }}
Type: ActionPreference
Parameter Sets: (All)
Aliases: proga
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThis cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
You must run Connect-LMAccount before running this command.