Position of RSSI block in RxTSP diagram is inconsistent #3

@Keno

Description

@Keno

The diagram in A2.14 of the SPI reference seems to indicate that the RxTSP's digital RSSI samples the signal strength before the AGC block:
image (6)

This is inconsistent with the following diagram in the main data sheet that indicates that RSSI is sampled after the gain is applied

Screen Shot 2022-08-22 at 5 46 01 PM

Either mode of operation could make sense here, but it'd be good to be consistent in the diagrams.