Add APC Back-UPS ES 850G2
Signed-off-by: Sheogorath <sheogorath@shivering-isles.com>
1 parent 0eca0ce commit 6b1b472

1 file changed

Lines changed: 115 additions & 0 deletions

File tree

Lines changed: 115 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,115 @@
1+
# DEVICE:URL:REPORT: https://github.com/networkupstools/nut-ddl/pull/40
2+
3+
# DEVICE:COMMENT:
4+
# Device dump generated by ./nut-ddl-dump.sh on Sat, 16 Mar 2024 15:42:38 +0100
5+
# DEVICE:EOC
6+
7+
# :; upsc ups
8+
battery.charge: 100
9+
battery.charge.low: 10
10+
battery.charge.warning: 50
11+
battery.date: 2001/09/25
12+
battery.mfr.date: 2022/12/13
13+
battery.runtime: 1572
14+
battery.runtime.low: 120
15+
battery.type: PbAc
16+
battery.voltage: 13.5
17+
battery.voltage.nominal: 12.0
18+
device.mfr: American Power Conversion
19+
device.model: Back-UPS ES 850G2
20+
device.serial: 5B2250T99999
21+
device.type: ups
22+
driver.name: usbhid-ups
23+
driver.parameter.pollfreq: 30
24+
driver.parameter.pollinterval: 2
25+
driver.parameter.port: auto
26+
driver.parameter.synchronous: auto
27+
driver.version: 2.8.0
28+
driver.version.data: APC HID 0.98
29+
driver.version.internal: 0.47
30+
driver.version.usb: libusb-1.0.26 (API: 0x1000109)
31+
input.sensitivity: medium
32+
input.transfer.high: 266
33+
input.transfer.low: 180
34+
input.voltage: 238.0
35+
input.voltage.nominal: 230
36+
ups.beeper.status: enabled
37+
ups.delay.shutdown: 20
38+
ups.firmware: 938.a2 .I
39+
ups.firmware.aux: a2
40+
ups.load: 18
41+
ups.mfr: American Power Conversion
42+
ups.mfr.date: 2022/12/13
43+
ups.model: Back-UPS ES 850G2
44+
ups.productid: 0002
45+
ups.realpower.nominal: 520
46+
ups.serial: 5B2250T07387
47+
ups.status: OL
48+
ups.test.result: No test initiated
49+
ups.timer.reboot: 0
50+
ups.timer.shutdown: -1
51+
ups.vendorid: 051d
52+
53+
# DEVICE:COMMENT-BLOCK:FIXME:UPSRW: ups
54+
# [battery.charge.low]
55+
# Remaining battery level when UPS switches to LB (percent)
56+
# Type: STRING
57+
# Maximum length: 10
58+
# Value: 10
59+
#
60+
# [battery.mfr.date]
61+
# Battery manufacturing date
62+
# Type: STRING
63+
# Maximum length: 10
64+
# Value: 2022/12/13
65+
#
66+
# [battery.runtime.low]
67+
# Remaining battery runtime when UPS switches to LB (seconds)
68+
# Type: STRING
69+
# Maximum length: 10
70+
# Value: 120
71+
#
72+
# [input.sensitivity]
73+
# Input power sensitivity
74+
# Type: STRING
75+
# Maximum length: 10
76+
# Value: medium
77+
#
78+
# [input.transfer.high]
79+
# High voltage transfer point (V)
80+
# Type: STRING
81+
# Maximum length: 10
82+
# Value: 266
83+
#
84+
# [input.transfer.low]
85+
# Low voltage transfer point (V)
86+
# Type: STRING
87+
# Maximum length: 10
88+
# Value: 180
89+
#
90+
# [ups.delay.shutdown]
91+
# Interval to wait after shutdown with delay command (seconds)
92+
# Type: STRING
93+
# Maximum length: 10
94+
# Value: 20
95+
# DEVICE:EOC
96+
97+
# DEVICE:COMMENT-BLOCK:FIXME:UPSCMD: ups
98+
# Instant commands supported on UPS [ups]:
99+
#
100+
# beeper.disable - Disable the UPS beeper
101+
# beeper.enable - Enable the UPS beeper
102+
# beeper.mute - Temporarily mute the UPS beeper
103+
# beeper.off - Obsolete (use beeper.disable or beeper.mute)
104+
# beeper.on - Obsolete (use beeper.enable)
105+
# load.off - Turn off the load immediately
106+
# load.off.delay - Turn off the load with a delay (seconds)
107+
# shutdown.reboot - Shut down the load briefly while rebooting the UPS
108+
# shutdown.stop - Stop a shutdown in progress
109+
# test.battery.start.deep - Start a deep battery test
110+
# test.battery.start.quick - Start a quick battery test
111+
# test.battery.stop - Stop the battery test
112+
# test.panel.start - Start testing the UPS panel
113+
# test.panel.stop - Stop a UPS panel test
114+
# DEVICE:EOC
115+