| 1 | +# DEVICE:URL:REPORT: https://github.com/networkupstools/nut/issues/2727 |
| 2 | + |
| 3 | +# DEVICE:COMMENT: |
| 4 | +# The UPS looks to be working with the `nutdrv_qx` driver, |
| 5 | +# different status events are properly reported. |
| 6 | +# |
| 7 | +# The (v2.8.0) `nut-scanner` tool suggested `nutdrv_qx` driver |
| 8 | +# according to vendorid/productid which is used in many unrelated |
| 9 | +# devices, that driver supports the (Qx) protocol here. |
| 10 | +# DEVICE:EOC |
| 11 | + |
| 12 | +# DEVICE:COMMENT-BLOCK:UPSCONF: |
| 13 | +# maxretry = 1 |
| 14 | +# pollinterval = 2 |
| 15 | +# battery_voltage_reports_one_pack |
| 16 | +# |
| 17 | +# [gc2000va] |
| 18 | +# driver = nutdrv_qx |
| 19 | +# protocol = q1 |
| 20 | +# port = auto |
| 21 | +# desc = "Green Cell PowerProof 2000VA UPS05" |
| 22 | +# chargetime = 28800 |
| 23 | +# idleload = 4 |
| 24 | +# default.battery.type = PbAcid |
| 25 | +# default.battery.capacity.nominal = 18.0 |
| 26 | +# default.battery.charge.low = 10 |
| 27 | +# default.battery.charge.warning = 50 |
| 28 | +# default.battery.voltage.nominal = 24 |
| 29 | +# default.battery.voltage.low = 21.00 |
| 30 | +# default.battery.voltage.high = 25.00 |
| 31 | +# default.battery.packs = 2 |
| 32 | +# runtimecal = 2340,8,4740,4 |
| 33 | +# default.input.frequency.nominal= 50.0 |
| 34 | +# default.input.voltage.nominal= 230.0 |
| 35 | +# default.output.current.nominal = 8.0 |
| 36 | +# default.output.frequency.nominal = 50.0 |
| 37 | +# default.output.voltage.nominal = 230.0 |
| 38 | +# default.ups.mfr = "Green Cell" |
| 39 | +# default.ups.model = "PowerProof 2000VA UPS05" |
| 40 | +# default.ups.mfr.date = "2024/12/17" |
| 41 | +# default.ups.vendor = "Fry's Electronics" |
| 42 | +# default.ups.product = "MEC0003" |
| 43 | +# default.ups.power.nominal = "2000" |
| 44 | +# default.ups.realpower.nominal = "1200" |
| 45 | +# DEVICE:EOC |
| 46 | + |
| 47 | +battery.capacity.nominal: 18.0 |
| 48 | +battery.charge: 100 |
| 49 | +battery.charge.low: 10 |
| 50 | +battery.charge.warning: 50 |
| 51 | +battery.packs: 2 |
| 52 | +battery.runtime: 4468 |
| 53 | +battery.type: PbAcid |
| 54 | +battery.voltage: 27.40 |
| 55 | +battery.voltage.high: 25.00 |
| 56 | +battery.voltage.low: 21.00 |
| 57 | +battery.voltage.nominal: 24 |
| 58 | +device.mfr: Green Cell |
| 59 | +device.model: PowerProof 2000VA UPS05 |
| 60 | +device.type: ups |
| 61 | +driver.name: nutdrv_qx |
| 62 | +driver.parameter.chargetime: 28800 |
| 63 | +driver.parameter.idleload: 4 |
| 64 | +driver.parameter.pollfreq: 30 |
| 65 | +driver.parameter.pollinterval: 2 |
| 66 | +driver.parameter.port: auto |
| 67 | +driver.parameter.protocol: q1 |
| 68 | +driver.parameter.runtimecal: 2340,8,4740,4 |
| 69 | +driver.parameter.synchronous: auto |
| 70 | +driver.version: 2.8.0 |
| 71 | +driver.version.data: Q1 0.07 |
| 72 | +driver.version.internal: 0.32 |
| 73 | +driver.version.usb: libusb-1.0.26 (API: 0x1000109) |
| 74 | +input.frequency: 50.1 |
| 75 | +input.frequency.nominal: 50.0 |
| 76 | +input.voltage: 238.7 |
| 77 | +input.voltage.fault: 238.7 |
| 78 | +input.voltage.nominal: 230.0 |
| 79 | +output.current.nominal: 8.0 |
| 80 | +output.frequency.nominal: 50.0 |
| 81 | +output.voltage: 239.2 |
| 82 | +output.voltage.nominal: 230.0 |
| 83 | +ups.beeper.status: enabled |
| 84 | +ups.delay.shutdown: 30 |
| 85 | +ups.delay.start: 180 |
| 86 | +ups.load: 3 |
| 87 | +ups.mfr: Green Cell |
| 88 | +ups.mfr.date: 2024/12/17 |
| 89 | +ups.model: PowerProof 2000VA UPS05 |
| 90 | +ups.power.nominal: 2000 |
| 91 | +ups.product: MEC0003 |
| 92 | +ups.productid: 0000 |
| 93 | +ups.realpower.nominal: 1200 |
| 94 | +ups.status: OL |
| 95 | +ups.type: offline / line interactive |
| 96 | +ups.vendor: Fry's Electronics |
| 97 | +ups.vendorid: 0001 |