"info": {
"title": "OMA/IPSO Stopwatch (Object ID 3350)",
"version": "2022-02-22",
"copyright": "Copyright 2019 Open Mobile Alliance.",
"license": "BSD-3-Clause"
},
"namespace": {
"oma": "https://onedm.org/ecosystem/oma"
},
"defaultNamespace": "oma",
"sdfObject": {
"Stopwatch": {
"label": "Stopwatch",
"description": "An ascending timer that counts how long time has passed since the timer was started after reset.",
"sdfProperty": {
"Cumulative_Time": {
"label": "Cumulative Time",
"description": "The total time in seconds that the timer input is true. Writing a 0 resets the time.",
"type": "number",
"unit": "s"
},
"On_Off": {
"label": "On/Off",
"description": "On/off control. Boolean value where True is On and False is Off.",
"type": "boolean"
},
"Digital_Input_Counter": {
"label": "Digital Input Counter",
"description": "The cumulative value of active state detected.",
"writable": false,
"type": "integer"
},
"Application_Type": {
"label": "Application Type",
"description": "The application type of the sensor or actuator as a string depending on the use case.",
"type": "string"
},
"Timestamp": {
"label": "Timestamp",
"description": "The timestamp of when the measurement was performed.",
"writable": false,
"type": "number",
"sdfType": "unix-time"
},
"Fractional_Timestamp": {
"label": "Fractional Timestamp",
"description": "Fractional part of the timestamp when sub-second precision is used (e.g., 0.23 for 230 ms).",
"writable": false,
"type": "number",
"unit": "s",
"minimum": 0,
"maximum": 1
},
"Measurement_Quality_Indicator": {
"label": "Measurement Quality Indicator",
"description": "Measurement quality indicator reported by a smart sensor. 0: UNCHECKED No quality checks were done because they do not exist or can not be applied. 1: REJECTED WITH CERTAINTY The measured value is invalid. 2: REJECTED WITH PROBABILITY The measured value is likely invalid. 3: ACCEPTED BUT SUSPICIOUS The measured value is likely OK. 4: ACCEPTED The measured value is OK. 5-15: Reserved for future extensions. 16-23: Vendor specific measurement quality.",
"writable": false,
"type": "integer",
"minimum": 0,
"maximum": 23
},
"Measurement_Quality_Level": {
"label": "Measurement Quality Level",
"description": "Measurement quality level reported by a smart sensor. Quality level 100 means that the measurement has fully passed quality check algorithms. Smaller quality levels mean that quality has decreased and the measurement has only partially passed quality check algorithms. The smaller the quality level, the more caution should be used by the application when using the measurement. When the quality level is 0 it means that the measurement should certainly be rejected.",
"writable": false,
"type": "integer",
"minimum": 0,
"maximum": 100
}
},
"sdfAction": {},
"sdfRequired": [
"#/sdfObject/Stopwatch/sdfProperty/Cumulative_Time"
]
}
}
}