-
Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathsdfobject-stopwatch.swagger.json
More file actions
145 lines (145 loc) · 4.81 KB
/
Copy pathsdfobject-stopwatch.swagger.json
File metadata and controls
145 lines (145 loc) · 4.81 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
{
"swagger": "2.0",
"info": {
"title": "OMA/IPSO Stopwatch (Object ID 3350)",
"version": "2022-02-22",
"license": {
"name": "BSD-3-Clause",
"x-copyright": "Copyright 2019 Open Mobile Alliance."
}
},
"schemes": [
"http"
],
"consumes": [
"application/json"
],
"produces": [
"application/json"
],
"paths": {
"/Omaipsostopwatchobjectid3350ResURI": {
"get": {
"description": " An ascending timer that counts how long time has passed since the timer was started after reset.",
"parameters": [
{
"$ref": "#/parameters/interface"
}
],
"responses": {
"200": {
"description": "",
"schema": {
"$ref": "#/definitions/Omaipsostopwatchobjectid3350"
}
}
}
}
}
},
"parameters": {
"interface": {
"in": "query",
"name": "if",
"type": "string",
"enum": [
"oic.if.s",
"oic.if.baseline"
]
}
},
"definitions": {
"Omaipsostopwatchobjectid3350": {
"properties": {
"rt": {
"description": "The Resource Type.",
"items": {
"enum": [
"oic.r.o.stopwatch"
],
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"n": {
"$ref": "https://openconnectivityfoundation.github.io/core/schemas/oic.common.properties.core-schema.json#/definitions/n"
},
"if": {
"description": "The OCF Interface set supported by this Resource.",
"items": {
"enum": [
"oic.if.s",
"oic.if.baseline"
],
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"Cumulative_Time": {
"description": "The total time in seconds that the timer input is true. Writing a 0 resets the time.",
"x-label": "Cumulative Time",
"type": "number",
"x-unit": "s"
},
"On_Off": {
"description": "On/off control. Boolean value where True is On and False is Off.",
"x-label": "On/Off",
"type": "boolean"
},
"Digital_Input_Counter": {
"description": "The cumulative value of active state detected.",
"x-label": "Digital Input Counter",
"type": "integer",
"readOnly": true
},
"Application_Type": {
"description": "The application type of the sensor or actuator as a string depending on the use case.",
"x-label": "Application Type",
"type": "string"
},
"Timestamp": {
"description": "The timestamp of when the measurement was performed.",
"x-label": "Timestamp",
"x-sdfType": "unix-time",
"type": "number",
"readOnly": true
},
"Fractional_Timestamp": {
"description": "Fractional part of the timestamp when sub-second precision is used (e.g., 0.23 for 230 ms).",
"x-label": "Fractional Timestamp",
"maximum": 1,
"minimum": 0,
"type": "number",
"x-unit": "s",
"readOnly": true
},
"Measurement_Quality_Indicator": {
"description": "Measurement quality indicator reported by a smart sensor. 0: UNCHECKED No quality checks were done because they do not exist or can not be applied. 1: REJECTED WITH CERTAINTY The measured value is invalid. 2: REJECTED WITH PROBABILITY The measured value is likely invalid. 3: ACCEPTED BUT SUSPICIOUS The measured value is likely OK. 4: ACCEPTED The measured value is OK. 5-15: Reserved for future extensions. 16-23: Vendor specific measurement quality.",
"x-label": "Measurement Quality Indicator",
"maximum": 23,
"minimum": 0,
"type": "integer",
"readOnly": true
},
"Measurement_Quality_Level": {
"description": "Measurement quality level reported by a smart sensor. Quality level 100 means that the measurement has fully passed quality check algorithms. Smaller quality levels mean that quality has decreased and the measurement has only partially passed quality check algorithms. The smaller the quality level, the more caution should be used by the application when using the measurement. When the quality level is 0 it means that the measurement should certainly be rejected.",
"x-label": "Measurement Quality Level",
"maximum": 100,
"minimum": 0,
"type": "integer",
"readOnly": true
}
},
"type": "object",
"required": [
"Cumulative_Time"
]
}
}
}