Skip to content

Storage modelling issues #946

Description

@sanketpuranik

Hi,

I have been modelling storage with a load to reduce peaks and shift load according to market prices (no capacity optimization). Doing this i have realized few issues with the storage model:

  1. C rate parameter doesn't seem to work. I wanted a 100 kWh battery system to have C rate of 0.7. However when i run simulation with defined C rate the result show that the C rate is actually 1! i tried different C rated but the result is always a C rate of 1. so instead i am not using input and output power to define the same.

  2. input and output power efficiency not working. After i define these two efficiencies the result show that efficiency is not considered. For example if i set output efficiency of 97% and if outpower is 70kW, i would expect actual output power 3% less than 70 kW. Maybe it is about interpretation, the output power of 70 kW is considereing efficiency losses. But then this has to be clear in documentation on how the losses are accounted in the battery model.

  3. finally an open question: is it possible to separately size power capacity (kW) and energy capacity of the storage (kWh)?

I have attached relevant files with the issue (@ciaradunks).

timeseries_all_busses_UC1.xlsx
energy system v2 - Copy
BESS_CSx.csv
energyStorage.csv

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Fields

    No fields configured for issues without a type.

    Projects

    No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions